MASTER 600-700-900-1200
10
Pre-start checks
The following inspection must be performed before the start of each work session or after every four hours of
use, whichever is first. Please consult the service section for detailed guidance. If any fault is discovered, the
machine must not be used until the fault is rectified.
1. Thoroughly inspect the machine for signs of damage.
2. Check hoses, filler openings, drain plugs and any other areas for signs of leakage. Fix any leaks before
operating.
3. Check the engine oil level and top up if required. Use proper engine oil with the proper viscosity (SAE 10W-
30 is recommended).
4. Check the engine fuel level and top up as necessary. Use clean fuel. The use of contaminated fuel may
damage the fuel system.
5. Check for oil and fuel leaks.
Start and stop procedure
Improper operation can be hazardous. Read and understand this section before you start the
machine.
HONDA GX120 & GX160
1. Open the petrol tap by moving the fuel ON/OFF lever fully
to the right.
2. If starting the engine from cold, set the choke ON by moving
the choke lever fully to the left. If restarting a warm engine,
the choke is usually not required, however, if the engine has
cooled to a degree, partial choke may be required.
3. Turn the engine ON / OFF switch clockwise to the ‘I’ position.
4. Set the throttle to the idle position by moving the throttle
lever fully to the right. Do not start the engine on full throttle.
5. Taking a firm hold of the control handle and set the
centrifugal switch to ON if not already, grasp the recoil
starter handle with the other. Pull the recoil starter until engine resistance is felt, then let starter return.
6. Taking care not to pull the starter’s rope fully out, pull the starter handle briskly.
7. Repeat until the engine fires.
8. Once the engine fires gradually set the choke lever to the OFF position by moving it to the right.
9. If the engine fails to fi re after several attempts, follow the troubleshooting guide on page 12.
10. To stop the engine, set the throttle to idle and release the control switch safety switch. Alternatively turn
the engine ON/OFF switch anti-clockwise to the ‘O’ position.
11. Turn the petrol off.
CAUTION
Summary of Contents for MASTER 600
Page 18: ...MASTER 600 700 900 1200 18...
Page 34: ...MASTER 600 700 900 1200 34...
Page 50: ...MASTER 600 700 900 1200 50...
Page 66: ...MASTER 600 700 900 1200 66...
Page 69: ...MASTER 600 700 900 1200 69 67 68 70 71 71 72 73 74 74 75 78 79 80 81...
Page 71: ...MASTER 600 700 900 1200 71 WARNING MASTER...
Page 72: ...MASTER 600 700 900 1200 72 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 6 7 8 9...
Page 73: ...MASTER 600 700 900 1200 73 1 1 M12 x 90 x1 M12 x 75 x1 30 2 1 3 M8 2 M8 4 3 1 4 2 3 4 4 4 5 4...
Page 76: ...MASTER 600 700 900 1200 76 2 3 10...
Page 77: ...MASTER 600 700 900 1200 77 Paclite MASTER 900 1200...
Page 78: ...MASTER 600 700 900 1200 78 MASTER Paclite Paclite Paclite 4 20 3 50 6 100...
Page 82: ...MASTER 600 700 900 1200 82...
Page 98: ...MASTER 600 700 900 1200 98...
Page 114: ...MASTER 600 700 900 1200 114...
Page 130: ...MASTER 600 700 900 1200 130...
Page 146: ...MASTER 600 700 900 1200 146...
Page 147: ...MASTER 600 700 900 1200 147...