Service and maintenance
MAINTENANCE
The Paclite MASTER Trowel is designed to give many years of trouble free operation. It is, however, important
that the simple regular maintenance listed in this section is carried out. It is recommended that an approved
Paclite Equipment dealer carry out all major maintenance and repairs. Always use genuine Paclite replacement
parts, the use of spurious parts may void your warranty. Before any maintenance is carried out on the machine,
switch off the engine and disconnect the HT lead from the spark plug. Always set the machine on level ground
to ensure any fluid levels will be correctly read. Only use recommended oils.
RUNNING IN PERIOD
When the trowel is first used from new, the engine oil must be changed after the initial running in period. (see
engine manual for full details).
MACHINE CLEANING
Clean the machine after it has been used to prevent the collection of hardened cement. The blades can usually
be cleaned with a high-pressure hose and water while the concrete is still wet. Hard cement/concrete is very
difficult to remove. Immediately replace any labels/stickers should you notice that they are worn, missing, or
damaged.
CHANGING BLADES
Be careful when changing old blades for new. Due to the way the blades wear, the old blades
become very sharp and can cut easily. Wear heavy duty gloves to avoid injury.
BLADES MUST BE REPLACED AS A SET!!!
Rountine maintenance
Daily
After first 4
hrs / weekly
First month /
20 hours
Every 3
months
/ 50 hrs
Every 6
months
/ 100 hrs
Air Filter
Check condition
•
•
Clean/Replace
•
Engine Oil
Check level
•
Change
•
•
Cutout Switch
Check
•
Belt Tension
Check
•
Spark Plug
Check/Clean
•
CAUTION
Summary of Contents for MASTER 600
Page 18: ...MASTER 600 700 900 1200 18...
Page 34: ...MASTER 600 700 900 1200 34...
Page 50: ...MASTER 600 700 900 1200 50...
Page 66: ...MASTER 600 700 900 1200 66...
Page 69: ...MASTER 600 700 900 1200 69 67 68 70 71 71 72 73 74 74 75 78 79 80 81...
Page 71: ...MASTER 600 700 900 1200 71 WARNING MASTER...
Page 72: ...MASTER 600 700 900 1200 72 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 6 7 8 9...
Page 73: ...MASTER 600 700 900 1200 73 1 1 M12 x 90 x1 M12 x 75 x1 30 2 1 3 M8 2 M8 4 3 1 4 2 3 4 4 4 5 4...
Page 76: ...MASTER 600 700 900 1200 76 2 3 10...
Page 77: ...MASTER 600 700 900 1200 77 Paclite MASTER 900 1200...
Page 78: ...MASTER 600 700 900 1200 78 MASTER Paclite Paclite Paclite 4 20 3 50 6 100...
Page 82: ...MASTER 600 700 900 1200 82...
Page 98: ...MASTER 600 700 900 1200 98...
Page 114: ...MASTER 600 700 900 1200 114...
Page 130: ...MASTER 600 700 900 1200 130...
Page 146: ...MASTER 600 700 900 1200 146...
Page 147: ...MASTER 600 700 900 1200 147...