background image

Instructions for Use

U5117 ISS B / MAR 2013

PAG Ltd.

 565 Kingston Road, Raynes Park, London SW20 8SA, UK

E

 sales@paguk.com  •  

+44 (0)20 8543 3131  •  

F

 +44 (0)20 8540 4116  •  

www.paguk.com

When the battery is fully charged the display will indicate 100%.

4.6

Run-Time Display:

When connected to a camera that is turned on, a second press of the
battery’s display button will show a predicted run-time against the
given load, expressed in hours and minutes.

The battery requires a minimum of 5 seconds before it is able to give
an accurate run-time prediction.

PAG L96T batteries maintain an accurate state-of-charge display by
tracking their performance, and adjusting the calibration values to
compensate for the ageing of the cells. They do not require a periodic
‘service charge’ to maintain display accuracy.

4.7

In-Viewfinder Battery Status (V-Mount & PAGlok Models only)

Battery status can be shown as a percentage of available capacity in
the viewfinders of cameras designed to accept this data. Different data
standards are used by camera and battery manufacturers; PAG L96T
batteries automatically adjust the data output standard to support the
following: SMB (Sony), I

2

C (IDX) and analogue 0V to 5V (Anton-Bauer).

L96T batteries can be programmed easily by the user to also provide
capacity data in the viewfinders of RED cameras. Press the display
button twice, holding down on the second press until ‘RED’ appears on
the display. This indicates that the battery is now compatible with the
RED data protocol (reversed SMB). When the battery is connected to a
camera with a different data protocol it will automatically adjust to
communicate with that system. To return to RED compatibility repeat the
two-button-press process.

5.1

Notwithstanding any provision of any agreement the following
guarantee is exclusive: PAG Limited guarantees each PAG L96T battery
it manufactures to be free of defects in material and workmanship
under normal use and service for 

2 YEARS 

from the date of purchase.

This guarantee extends only to the original purchaser. This guarantee
shall not apply to fuses or any product or parts which have been
subject to misuse, neglect, accident or abnormal conditions of
operation.

5.2

In the event of failure of a product covered by this guarantee, PAG
Limited will repair and calibrate equipment returned to an authorised
Service Facility within the period of the guarantee, provided the
guarantor’s examination discloses to its satisfaction the product was
defective. The guarantor may, at its option, replace the product in lieu
of repair. With regard to any equipment returned within this period,
said repairs or replacements will be made without charge. If the failure
has been caused by misuse, neglect, accident or abnormal conditions
of operation, repairs will be billed at a nominal cost. In such a case,
an estimate will be submitted before work is started, if requested.

5.3

The foregoing guarantee is in lieu of all other guarantees, express or
implied, including but not limited to any implied guarantee or
merchantability, fitness or adequacy for any particular purpose or use.
PAG Limited shall not be liable for any special, incidental, or conse-
quential damages, whether in contract, tort, or otherwise.

4.1

Charging

IMPORTANT: THE BATTERY IS ELECTRONICALLY PROTECTED, AND WILL
NOT ACCEPT A CHARGE FROM UNSUITABLE CHARGERS.

PAGlok Model:

  the battery can ONLY be charged from a PAG ACS

charger that is designed to charge PAG Lithium-Ion batteries.
A software upgrade may be required for PAGlok chargers manufactured
prior to November 2008, to enable them to charge the PAG L96T battery.

V-Mount Compatible Model:

  the battery can be charged from a

PAG V-Mount compatible charger, such as the PAGlink PL16 Model
9707, PAGlink Cube Model 9708, PAGlink Micro Charger Model 9710
and PAG Cube Model 9702V. A software upgrade may be required for
PAGlok or PAG Snap-on compatible chargers manufactured prior to
November 2008, to enable them to charge the V-Mount L96T via the
front PP90 sockets, using charge adaptor Model 9617.

Gold-Mount

 

Compatible Model:

 the battery can be charged from an

Anton Bauer Li-Ion charger or a PAG ACS charger that is designed to
charge PAG Li-Ion batteries, e.g. Pulsar, Quasar or AR Series 2 chargers.
A software upgrade may be required for PAG chargers manufactured prior
to November 2008, to enable them to charge the PAG L96T battery.

READ THE CHARGER HANDBOOK BEFORE ATTEMPTING TO CHARGE THE
BATTERY.

4.2

Protection Shutdown

IMPORTANT: If the battery is discharged at too high a rate, even
momentarily, it will disconnect its output. This is a safety feature.

It should be noted that even if the nominal consumption of a camera
and light falls within the rating of the battery, high current surges can
occur when the recorder or the light is turned on which may be
sufficient to exceed the rating and trip the protection circuit.

IMPORTANT: A tungsten-filament light draws a high current pulse when
it is turned on from cold, and this may trigger the over-current
protection. This can be avoided by using a suitable light (refer to
Section 3.7 above).

4.3

Battery Output Re-set Procedure

If the battery has been shut down by its protection circuit it can be
recovered by simply removing it from the load and pressing the
display button, provided the battery still retains some charge.

4.4

Thermal Protection

When the battery has been discharged at a high rate it will become
warm, and it is advisable to let it cool before charging it. The battery
should be charged within the temperature range +10°C to +40°C.

4.5

Capacity Indication

The battery is able to display its charge status as a percentage.

A single button press of the display, whether the battery is off or
on-load, shows a percentage figure of available capacity.

When battery capacity drops below 5% the display will indicate that
the battery should be charged by pointing to the empty battery
symbol.

Guarantee

Reviews: