background image

Pahlén AB, Box 728, SE-194 27 Upplands Väsby, Sweden

Tel. +46 8 594 110 50, Fax +46 8 590 868 80, e-mail: info@pahlen.se, www.pahlen.com

A ( 1 : 1 )

Art.no.

Rev.no.

Scale

Designed by:

Approved by:

Revised by:  Date

Drawn by:  Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 

The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, Sweden

Phone +46 8 59411050, Fax +46 8 59086880

 

TS

2012-06-21

överhettningsskydd

Demontering lock

 

M11668 0

A

Th

is

 d

oc

um

en

t a

nd

 it

co

nt

en

ts

 a

re

 th

ex

cl

us

iv

pr

op

er

ty

 o

f P

ah

ns

 a

nd

 m

ay

 n

ot

 b

co

pi

ed

re

pr

od

uc

ed

, t

ra

ns

m

itt

ed

 o

r c

om

m

un

ic

at

ed

 to

 a

 th

ird

 

pa

rty

, o

r u

se

fo

r a

ny

 p

ur

po

se

 w

ith

ou

t w

rit

te

pe

rm

is

si

on

.

Cap

A ( 1 : 1 )

Th

is

 d

oc

um

en

t a

nd

 it

co

nt

en

ts

 a

re

 th

ex

cl

us

iv

pr

op

er

ty

 o

f P

ah

ns

 a

nd

 m

ay

 n

ot

 b

co

pi

ed

re

pr

od

uc

ed

, t

ra

ns

m

itt

ed

 o

r c

om

m

un

ic

at

ed

 to

 a

 th

ird

 

pa

rty

, o

r u

se

fo

r a

ny

 p

ur

po

se

 w

ith

ou

t w

rit

te

pe

rm

is

si

on

.

Art.no.

Rev.no.

Scale

Designed by:

Approved by:

Revised by:  Date

Drawn by:  Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 

The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, Sweden

Phone +46 8 59411050, Fax +46 8 59086880

 

TS

2012-06-21

överhettningsskydd

Demontering lock

 

M11668 0

A

Cap

Reset button

Protective cap

Reset

button

Protective cap

Electric heater Aqua HL line

Item no. 141800-141832, 141800T- 141832T

ENGLISH 

1

Installation instruction

MA45-11E

2012

The electric heater must be installed horizontally as shown on the drawing, so that it is always full of water. The heater must never be 

started or left switched on unless it is completely full of water (fire risk).

If the heater is positioned against combustible material, a fireproof panel or similar must be placed between the heater and the wall. 

The panel must extend 10 cm outside the outer dimensions of the heater.

Do not cover the heater.

The warranty is void if the heater has been incorrectly installed or used.

Important! 

The standard heater must not be used in aggressive water, salt water or for pools with a chlorinator/salt generator.

In such circumstances an Electric heater Aqua HL line titanium is required.

“Persons with limited physical or mental capacity (including children) must not use the device without instructions on how to use it 

safely”, according to IEC 60335-1.

Pipe installation

The heater must be installed in the return line to the pool after

 the filter; see the installation drawing.

Do not install a shut-off valve between the heater and the pool. If a valve is required, install a check valve. If there is a risk of freezing 

where the heater is located, the installation must allow all water to be drained from the heater.

The outlet of the electric heater must not be connected to any tap or coupling other than in accordance with the installation drawing.

Electrical installation

The electrical installation work must be done by a qualified electrician.

The pipework must be complete before the electrical installation work is done.

Connect the motor protection auxiliary relay of the circulation pump to P1:1 and 2, see the enclosed wiring diagram for voltage and 

number of phases. When the motor protection is switched on, the circuit shall be closed.

If there is no external motor protection the connections 1 and 2 on P1shall be interconnected (clamped).

Check that the connecting cable cannot come into contact with the hot parts of the element.

Starting

1.  Start the pool water circulation pump.

  Check that the water is circulating normally in the installation before switching on the heater. The heater must be completely full of 

  water before the power is switched on.

2.  Switch on the power to the heater.

3.  Set the desired pool temperature.

4.  Check the flow switch by turning off the flow of water through the heater with a shut-off valve. The contactor should trip.

5.  Turn on the water. The contactor should now close (after 15 sec.).

6.  The heater will now heat the pool water to the desired temperature.

Setting the temperature

Press once (on the blue or red arrow key) - the display starts to flash.

Press once more - a temperature is now displayed.

Change the temperature up and down with the arrow keys until the required temperature is set. 

Red = warmer, blue = colder in steps of 0,5°C.

After the setting is completed, the display will return to showing the actual pool temperature with a fixed light.

Operation

For the heater to work, the pool water must be circulating.

The yellow LED marked “Heating” is lit when the heater is working and goes out when the correct temperature has been reached.

The display constantly shows the current temperature of the water. The set temperature can be changed at any time (see Setting the 

temperature). To see the set temperature, press once (the display flashes). NOTE: The set temperature is retained in the memory after 

a power failure.

NOTE: Always switch off the power to the heater before backwashing and before cleaning the filter.

Trouble shooting

If the heater does not start:

1.  Check the fuses

2.  The overheating protection may have tripped: 

  -Losen the protective cap, see fig beside.

  -Press the reset button on the connection box. 

  -Put the cap back.

3.  Check the flow rate. The flow switch in the heater is 

  designed for a minimum flow of 90 litres/min.

4.  Set the thermostat to a higher temperature.

 

Follow these instructions:

  

Standard 

Titanium

 

Chlorine content: 

max 3 mg/l (ppm) 

max 3 mg/l (ppm

 

Chloride (salt) content:   max 250 mg/l 

-

 

pH:  

7.2-7.8 

7.2-7.8

 

Alkalinity:  

60-120 mg/l (ppm) 

60-120 mg/l (ppm)

 

Calcium hardness:  

200-1000 mg/l (ppm) 

200-1000 mg/l (ppm)

 

Max temperature:  

45 °C 

45 °C

 

Minimum flow rate: 

90 l/min. 

90 l/min.

 

Max pressure: 

2 bar 

2bar

Error codes 

E1

 = flow switch, circulation pump

E2

 = pool sensor

E7

 = control circuit contactor, overheating limit control

Hi

 = pool temperature above +45ºC  

Protective cap

Reset

button

Protective cap

Summary of Contents for Aqua HL Series

Page 1: ...Tryck en g ng p bl eller r d piltangent displayen b rjar blinka Tryck en g ng till en temperatur visas nu ndra den temperaturen upp eller ned med piltangenterna till nskad pooltemperatur R d varmare...

Page 2: ...141800 141832 141800T 141832T SVENSKA 2 Installation Inkopplingsschema el 1 fas 230V AC Br ddavlopp Bottenavlopp Pump Filter Avlopp Inlopp Backventil Belysning Belysning Elv rmare Aqua HL line Jet Swi...

Page 3: ...kopplingsschema el 3 fas 230V AC Kretskort f r styrkontroll verhettnings skydd Fl desvakt Temp givare pool Elpatron 3 15kW Externt motorskydd 1 fas Externt motorskydd 3 fas Kretskort f r display Krets...

Page 4: ...tallation The electrical installation work must be done by a qualified electrician The pipework must be complete before the electrical installation work is done Connect the motor protection auxiliary...

Page 5: ...V AC Display circuit board Control circuit board Overheating limit control Flow switch Temp sensor pool Heating element 3 6kW type A External motor protection 1 phase External motor protection 3 phase...

Page 6: ...ection 1 phase External motor protection 3 phase Display circuit board Control circuit board Overheating limit control Flow switch Temp sensor pool Heating element 3 15kW External motor protection 1 p...

Page 7: ...t Elektroinstallation Die Elektroinstallation darf nur von einem dazu befugten Elektriker erfolgen Die Elektroinstallation erfolgt nach fertiger Rohrinstallation Das Motorschuntzhilfsrelais der Umz lz...

Page 8: ...kimmer Bodenablauf Pumpe Filter Elektroheizer Aqua HL line Ablauf Einlauf R ckschlagklappe Beleuchtung Beleuchtung Jet Swim Display Schaltplatte Steuerkontrolle Schaltplatte berhitzung schutz Durchflu...

Page 9: ...r Motorschutz 1 Phasen Externer Motorschutz 3 Phasen Display Schaltplatte Steuerkontrolle Schaltplatte berhitzung schutz Durchfluss w chter Pool temperatur geber Heizelement 3 15kW Externer Motorschut...

Page 10: ...ut written permission Cap A 1 1 This document and its contents are the exclusive property of Pahl ns and may not be copied reproduced transmitted or communicated to a third party or used for any purpo...

Page 11: ...46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com Drawing no M10690 2 080320 T S 400 Installation elv rmare Aqua HL line 500 800 1 230 AC 3 6 1 3 3 6 Aqua HL line Jet Swim Aqua...

Page 12: ...ands V sby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com 3 15 1 3 3 15 1 3 3 400 415 AC 3 230 AC Aqua HL line 141800 141832 141800T 141832T 3 MA45 11R 2012 F1 100...

Page 13: ...ement tre effectu e par un lectricien agr L installation lectrique doit tre effectu e apr s avoir termin l installation de la tuyauterie Connectez la protection relais auxilliare de la pompe de circul...

Page 14: ...thermique Contr leur de d bit Capteur de temp piscine Cartouche lectrique 3 6kW Type A Protection de moteur externe monophas e Protection de moteur externe triphas e Sch ma de branchement lectrique Mo...

Page 15: ...de moteur externe triphas e Sch ma de branchement lectrique Triphas 400 415V AC Afficheur carte de circuit Commande de carte de circuit Protection thermique Contr leur de d bit Capteur de temp piscine...

Reviews: