Pahlén AB, Box 728, SE-194 27 Upplands Väsby, Sweden
Tel. +46 8 594 110 50, Fax +46 8 590 868 80, e-mail: info@pahlen.se, www.pahlen.com
Maxi Heat ( 3N~ 400/415V )
Electric heater with electronic thermostat
OH
K1B
K2B
K3B
K4B
K1A
K2A
K3A
K4A
H1 (heater)
H2 (heater)
H3 (heater)
H4 (heater)
L1
L1
bk 4mm²
gy
gn
bu
or
or
wh br bk
bk 6mm²
bk 6mm²
bk 6mm²
bk 6mm²
bk 4mm²
bk 4mm²
bk 4mm²
br 4mm²
br 6mm²
br 6mm²
br 6mm²
br 6mm²
br 4mm²
br 4mm²
br 4mm²
wh 4mm²
wh 6mm²
wh 6mm²
wh 6mm²
wh 6mm²
wh 4mm²
wh 4mm²
wh 4mm²
yl/gn
bu
L2
L2
L3
L10
L3
N
E10031-4
101125 T.S
3N~
400V/415V
Control
circuit board
www.pahlen.com
www.pahlen.com
Display
circuit board
+45°
Transformer
J2
Option:
External
control
J5
J9
J6
J4
J7
J8
P2:
P1:
1
2
N
K4 K3 K2 K1
L
Pump circulation
Flow switch
Pool temp. Sensor
Overheating limit control
F1
F2
L1
N
M
A1
A1
A1
A1
A1
A1
A1
A1
A2
A2
A2
A2
A2
A2
A2
A2
L1
L2
L3
External motor protection
1-phase
External motor protection
3-phase
Assembly drawing
(tank)
M
F5
H3
H4
H2
H1
Pink
Pink
Pink
Pink
White
White
White
White
White
White
White
White
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Pink
Pink
Pink
Pink
F1
F2
F3
F4
Elektroheizer Maxi Heat Digital
MA45-17T
201
5
Installationsanweisung
DEUTSCH
5
Umwälzpumpe
Pooltemp.Sensor
Überhitzungschutz
Display
PCB
Steuerung
PCB
Externer Motorschutz
3-Phasen
Externer Motorschutz
1-Phase
Option:
Externe Steuerung
Übersichszeichnung
Tonne
Maxi Heat Digital 3N~400/415V
H1 (Heizelement)
H2 (Heizelement)
H3 (Heizelement)
H4 (Heizelement)
Durchfluss-