Using the Maintenance Terminal
150-402-102-01, Revision 01
24
July 27, 1998
HRU-402 List 2
When no doublers are in use, the following Span Status screen displays:
Figure 11.
View Span Status Screen for Non-doubler Applications
At this screen you have the following options:
1
Press
to exit and return to the previous menu.
2
Press
to clear the current values.
3
Press
to update the current values.
TIME: 00:14:11
SPAN STATUS
DATE: 02/02/98
Circuit ID#:
ALARMS: NONE
LOOPBACK: OFF
POWER LEVEL: LOW
HLU
HRU
HDSL-1 HDSL-2 HDSL-1 HDSL-2
cur/min/max cur/min/max cur/min/max cur/min/max
MARGIN:
21/17/21 20/17/21 21/18/21 20/18/21
dB
PULSE ATTN:
19
19
19
19
dB
INS LOSS:
23
23
23
23
dB
PPM OFFSET:
00
00
06
05
ppm
24 HOUR ES:
00002
00004
00005
00007
seconds
24 HOUR UAS:
00016
00013
00002
00001
seconds
DS1 STATUS
HLU
HRU
24 HOUR BPV Seconds:
00000
00004
24 HOUR UAS Count:
00015
00001
Frame type:
ESF
ESF
Code type:
B8ZS
B8ZS
(E)xit (C)lear (U)pdate