background image

Section 350-231-164

Revision 01

10

HLU-231 List 6D

DS0

BLK

The DS0 blocking option can only be set through the Craft 
port with a terminal.  The 4-character HLU-231 List 6

D

 

front panel LED readout only displays the status of the 
blocking option.  BLK indicates at least one channel is 
blocked.

NONE*

NONE indicates no channels are blocked.

FRMG

AUTO*

Configures HiGain to operate in an auto-framing (AUTO) 
mode in which it continuously searches the input T1 bit 
stream for a valid Superframe or Extended Superframe 
pattern.  This feature is required for fractional T1 applica-
tions (DS0 blocking) where it insures proper channel time 
slot alignment.  While HiGain can also process unframed 
data in this AUTO mode, it is recommended that the UNFR 
mode be used for all unframed applications.  Using the 
AUTO mode for unframed  applications runs the risk of 
detecting "pseudo valid" frame sequences, which can 
affect the data integrity.

UNFR

Configures HiGain to operate in an unframed mode.  This 
mode disables the auto framing process and forces 
HiGain to function as a transparent bit pipe.

HAIS

2LP*

Causes HiGain to transmit the Alarm Indication Signal 
(AIS) signal at both the HLU and HRU T1 output ports 
when both of the HDSL loops are not in sync (Loss of 
Sync-Word).

1LP

Causes HiGain to transmit the AIS signal at both the HLU 
and HRU T1 output ports when either of the two HDSL 
loops is not in sync (LOSW) or if a margin alarm occurs.

SAIS

ENA*

Causes the HRU to transmit the AIS signal towards the 
Customer Interface (CI) when in NREM loopback.

DIS

Prevents the AIS signal from being transmitted to the net-
work interface and replaces it with the network test signal 
or by a quiet termination (Loss of Signal) depending on the 
list number of the HRU.

CONF

YES

Confirms that all operating modes (listed above) are to be 
updated to their current selections.

NO*

Prevents the most recently selected operating mode 
selections from being updated.  They remain as they were 
before the system option settings mode was entered.

HLU-231 List 6D System Options (Continued)

Mode

Selection

Description

Summary of Contents for HLU-231

Page 1: ...UICK INSTALLATION GUIDE PAIRGAIN TECHNOLOGIES INC SECTION 350 231 164 01 Revision History of this guide Revision 01 November 25 1997 A Initial Release Model List Part Number CLEI Code HLU 231 6D 150 1...

Page 2: ...isioning 6 Using the SEL and MODE Front Panel Buttons 6 Default Settings 6 Using the Craft port 7 System Settings 8 Testing 11 Alarms 11 Loopbacks 12 Four Character Diagnostic Messages 14 Specificatio...

Page 3: ...a complete HiGain High bit rate Digital Subscriber Line HDSL system This guide addresses HLU 231 List 6D operation when used with and without doublers For applications without doublers the HLU 231 Lis...

Page 4: ...Section 350 231 164 Revision 01 2 HLU 231 List 6D Features The HLU 231 Line Unit List 6D front panel features are...

Page 5: ...tional settings and alarms System option buttons MODE and SEL Select buttons used to set system modes Status LED Tri color LED that indicates system state Green Normal Operation Flashing Green HDSL Ac...

Page 6: ...rd Edge Connectors The HLU 231 card edge connector pinouts are shown below The following rules apply to the HLU 231 card edge connector If the shelf uses pin 23 remove resistor R39 from the HLU 231 bo...

Page 7: ...HLU 231 To install the HLU 231 into a PairGain shelf slide the unit into the shelf card guides for the desired slot then push the unit in until it is entirely within the card guide and the retaining l...

Page 8: ...g 2 Press the SEL button to step the display through all possible settings one at a time of the parameter being displayed 3 Press the MODE button to select the desired parameter and move to the next p...

Page 9: ...VT Terminal Emulation 2 Use a serial cable to connect the RS 232 COM port on the dumb terminal to the HLU 231 front panel Craft port 3 On each screen enter the key represented by the letter in parent...

Page 10: ...ON Selects the Extended Superframe ESF frame ZBTSI mode OFF Deslects the ESF frame ZBTSI mode LPBK DIS Configures the HLU 231 to ignore the 2 in 5 Smart Jack loopback command ENA Enables the HLU 231 t...

Page 11: ...gures the HiGain system to respond to the Wescom addressable repeater in band loopback codes A4LB Configures the HiGain system to respond to the Wescom Mod 1 addressable repeater in band loopback code...

Page 12: ...s HiGain to operate in an unframed mode This mode disables the auto framing process and forces HiGain to function as a transparent bit pipe HAIS 2LP Causes HiGain to transmit the Alarm Indication Sign...

Page 13: ...ges Message Full Name Description NONE No Alarms LLOS Local Loss of Signal No signal from HLU 231 local T1 inter face RLOS Remote Loss of Signal No signal from HRU remote T1 interface LOSW1or LOSW2 Lo...

Page 14: ...m in band codes or from the dumb terminal NLOC Network Local Loopback Loopback at HLU toward the network initi ated by upstream in band codes or from the dumb terminal CLOC Customer Local Loopback Loo...

Page 15: ...nd codes or the main tenance terminal NDU2 Network Doubler 2 Loopback The loopback at doubler 2 toward the net work initiated by in band codes or the main tenance terminal CDU1 Customer Doubler 1 Loop...

Page 16: ...op or Loop 3 The 2nd Doubler and HRU transceivers are trying to establish contact with each other on loops 1 or 2 of span 3 ACQ1 or ACQ2 Acquisition 1 or Acquisition 2 The HLU and HRU multiplexers are...

Page 17: ...ther HDSL pair in span 1 BAD RT No response from HRU The HLU does not receive any response from the HRU Thus the HRU s integrity is questionable VER HLU Software Version This is displayed during the S...

Page 18: ...ents on any PairGain documentation send mail to technical_publications pairgain com Type the product name and the sec tion number of the document in the subject area of the email message Technical Sup...

Page 19: ...ard system for obtaining current information on PairGain products product troubleshooting tips and aids accessing helpful utilities and for posting requests or questions This system is available 24 ho...

Page 20: ......

Reviews: