Section 150-319-124
Revision 03
Page 52
21.09
Figure 32 through Figure 34 show the Alarm
History screens for doubler applications. The alarms
are defined in Section A Paragraph 4.01. The LOS
and PWR system alarms are common to all spans.
Only the LOSW, ES and Margin are span-specific
alarms. The PWR-OPEN and PWR-SHRT alarms
indicate alarm conditions on the HLU-319. Neither
PWR alarm is available on the other spans. In Figure
32 through Figure 34, the “First” and “Last” columns
contain the time and date stamp of the first and last
occurrence of each alarm. The “Current” column
shows the status of each alarm. The “Count” column
lists the number of times each alarm occurred. All the
data can be cleared by pressing C (Clear). The
maximum non-overflowing count is 999. The Span 1
screen concerns alarms which occurred on the two
HDSL loops between the HLU-319, List 2D and the
first doubler (HDU1). The Span 2 screen refers either
to the loops between the first doubler (HDU1) and the
HRU-412, for one-doubler circuits, or, to the loops
between the first and second doublers (HDU1 and
HDU2), for two-doubler circuits. The Span 3 screen
refers to the loops between the second doubler and
the HRU-412, for two-doubler circuits.
TABLE 18. HLU-319, LIST 2D STATUS MENU MESSAGES
Message
Full Name
Description
ALARMS:
NONE
No Alarms
“None” indicates no alarms.
LLOS
Local Loss of Signal
No signal from HLU-319, List 2D local DSX-1 interface.
RLOS
Remote Loss of Signal
No signal from HRU-412 remote DS1 interface.
LOSW1
Loss of Sync Word 1
HDSL loop 1 has lost sync.
LOSW2
Loss of Sync Word 2
HDSL loop 2 has lost sync.
H1ES
HDSL Loop 1 Errored Second
Loop 1 CRCs have exceeded the user-selected ES threshold.
H2ES
HDSL Loop 2 Errored Second
Loop 2 CRC have exceeded the user-selected ES threshold.
DS1
Digital Service 1
T1 input BPVs, at either the HLU-319, List 2D or HRU-412, have
exceeded the user-selected ES threshold.
RAIS
Remote Alarm Indicating
Signal
Indicates an AIS (all “1”) pattern is being transmitted from the
remote T1 output port.
LAIS
Local Alarm Indicating Signal
Indicates an AIS (all “1”) pattern is being transmitted from the
local T1 output port.
MAL1
Margin Alarm 1
The margin on HDSL loop 1 has dropped below the threshold (0
to 15 dB) set by the user. Setting the threshold to 0 inhibits the
margin alarm.
MAL2
Margin Alarm 2
The margin on HDSL loop 2 has dropped below the threshold (0
to 15 dB) set by the user. Setting the threshold to 0 inhibits the
margin alarm.
CHREV
Channels Reversed
The loop 1 and loop 2 HDSL pairs are reversed at the HDU-451
or HRU-412 line input ports. Loop 1 is specified to carry the (-)
simplex DC voltage, and loop 2 is specified to carry (+) simplex
DC voltage.
ACO
Alarm CutOff
A minor alarm occurred and was retired to an ACO condition
after pressing the SEL button on the HLU front panel.
Table continued on next page