Section 150-319-124
Revision 03
Page 55
TABLE 20. HLU-319, LIST 2D FOUR-CHARACTER FRONT PANEL MESSAGES
Message
Full Name
Description
CREM
Customer Remote Loopback
Signal from customer is looped back to customer at HLU-
319.
NLOC
Network Local Loopback
DSX-1 signal is looped back to DSX-1 at HLU.
CLOC
Customer Local Loopback
Signal from customer is looped back to customer at HRU-
412.
NREM
Network Remote Loopback
DSX-1 signal is looped back to DSX-1 at HRU.
SMJK
Remote Smart-Jack Loopback
DSX-1 signal is looped back to DSX-1 at HRU.
TLOS
Transmit Loss Of Signal
HRU is in a logic loopback state caused by a loss of its
DS1 input from the CI, if ENAbled at the HRU via its
TLOS switch option.
FERR
Framing Bit Error occurred
Framing bit error occurred at HLU DSX-1 input.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the DSX-1 input
to the HLU-319.
SIG1
Signal 1
The HLU and the first doubler transceivers are trying to
establish contact with each other on loop 1 of span 1.
SIG2
Signal 2
The HLU and the first doubler transceivers are trying to
establish contact with each other on loop 2 of span 1.
S2L1
Signal 2 Loop 1
The first doubler is trying to establish contact with either
the HRU or the second doubler transceivers on loop 1 of
span 2.
S2L2
Signal 2 Loop 2
The first doubler is trying to establish contact with either
the HRU or the second doubler transceivers on loop 2 of
span 2.
S3L1
Signal 3 Loop 1
The second doubler and HRU transceivers are trying to
establish contact with each other on loop 1 of span 3.
S3L2
Signal 3 Loop 2
The second doubler and HRU transceivers are trying to
establish contact with each other on loop 2 of span 3.
ACQ1
Acquisition 1
The HLU and the first doubler multiplexers are trying to
establish synchronization over loop 1 of span 1
ACQ2
Acquisition 2
The HLU and the first doubler multiplexers are trying to
establish synchronization over loop 2 of span 1
Table continued on next page