PG-Flex FLL-712 List 3A
PairGain Engineering - Plant Series
Page 9
Figure 5 shows the pinouts for connecting the FLL-712 to a modem using a null-modem cable.
Using Data Carrier Detect (DCD) from the modem ensures that the FLL-712 line unit logs off if the
carrier signal disappears.
When configuring a modem, ensure that either the DIP switches or the software configuration is set
OFF for Carrier Detect (CD) override. This causes the modem to send CD signal when it connects
with another modem and to drop CD when it disconnects. Otherwise, if set ON, the FLL-712
connection functions correctly but does not log out when disconnected.
It is recommended that Data Terminal Ready (DTR) override be OFF. This allows a modem call
to terminate correctly when the FLL-712 drops DSR (which is null-modemed to DTR input on
the modem).
Figure 5. Connecting the FLL-712 to a Modem
The connection is set up as:
•
DCE with 8 data bits
•
1 stop bit
•
no parity
•
1200 to 9600 baud (9600 baud recommended)
The protocol requires DTR active from the terminal to prevent automatic log off.