Section 363-712-131-01
February 24, 1998
Revision 01
Page 18
PairGain Engineering - Plant Series
PG-Flex FLL-712 List 3A
Table 4. System Settings Menu Options (continued)
Parameter
Default Value
Description
All of the parameters discussed in the remainder of this table are stored in the CO line unit card NVRAM
and therefore will not normally change when power is cycled or cards are removed and reinserted.
E) Auto Logout Time
DISABLED
After logging on to a system, you are automatically logged out
after a time determined by the Auto Logout Time parameter:
•
DISABLED: The user is never automatically logged out.
(Note: If the user leaves the system without logging out,
and if Auto Logout Time is "DISABLED", the next
person who accesses the system can do so without
logging on and does not need a password).
•
5: Automatically logs out after 5 minutes.
•
30: Automatically logs out after 30 minutes.
•
60: Automatically logs out after 60 minutes.
F) Metered
Tone
Frequency
12
Metered tones are used for out-of-band signaling with coin
telephones, typically in international markets. A special
channel card is required to support this function.
G) Ring
Frequency
20
Determines the frequency of the ringing voltage on the
subscriber line. The values can be set to one of the following
parameters:
•
20: The ring generator is set to 20 Hz.
•
25: The ring generator is set to 25 Hz.
•
30: The ring generator is set to 30 Hz.
H) HDSL ES Alarm
Threshold
DISABLED
Sets the number of Error Seconds required before a minor
alarm is generated (dependent on the setting of the Alarm on
HDSL Threshold parameter). The count of Error Seconds is
reset to zero when the reset function is used on the HDSL
Performance History status screen. The values can be set to
one of the following parameters:
•
DISABLED: No minor alarm is generated, regardless of
the number of error seconds.
•
17: A minor alarm is generated after 17 error seconds.
•
170: A minor alarm is generated after 170 error seconds.