background image

Section 363-752-100
Revision 01

Page 4

4.  CERTIFICATION

4.01

FCC Compliance. The FRC-752 Channel Unit
complies with the limits for Class A digital devices

pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct
the interference at his own expense.

4.02

Refer to the installation section of the appropriate
instruction manual for the unit you are installing to

get information on:

• 

Cabling

• 

Proper connections

• 

Grounding

• 

Line vs. local power

4.03

All wiring external to the product(s) should follow
the provisions of the current edition of the National

Electrical Code.

5.  WARRANTY

5.01

PairGain Technologies warrants this product to be
free of defects and to be fully functional for a period

of 5 years from the date of original shipment, given proper
customer installation and regular maintenance. PairGain will
repair or replace any unit without cost during this period if
the unit is found to be defective for any reason other than
abuse or improper use or installation.

5.02

This module should not be field repaired. If it fails,
replace it with another unit and return the faulty unit

to PairGain for repair. Any modifications of the unit by
anyone other than an authorized PairGain representative will
void the warranty.

5.03

If a unit needs repair, call PairGain for a Return
Material Authorization (RMA) number and return

the defective unit, freight prepaid, along with a brief
description of the problem, to:

PairGain Technologies, Inc.
14402 Franklin Avenue
Tustin, CA 92680
ATTN:  Repair and Return Dept.
(800) 638-0031

5.04

PairGain will continue to repair faulty modules
beyond the warranty program at a nominal charge.

Contact your PairGain sales representative for details and
pricing.

B.  FUNCTIONAL DESCRIPTION

6.  OPERATIONAL CAPABILITIES

6.01

Each FRC-752 RT Channel Unit provides four
POTS interfaces between the RT and subscribers,

and performs the following functions:

• 

64 kbps A-Law PCM encoding

• 

Applies ringing voltage

• 

Generates forward disconnect

• 

Generates metering tones

• 

Detects an off-hook or ring-trip condition

• 

Connects a subscriber loop to a metallic test pair

• 

Protects against secondary surges and power line
cross

6.02

A block diagram of the FRC-752 is shown in
Figure 3.

Figure 3.  FRC-752 Block Diagram.

Summary of Contents for PG-FLEX RT FRL-752

Page 1: ...NS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 5 C INSTALLATION AND TEST 8 UNPACKING 5 9 TURN UP AND TESTING 5 10 TROUBLESHOOTING 5 CAUTION This product incorporates static sensitive components Proper electrostatic discharge procedures must be followed Figure 1 FRC 752 Channel Unit List 1 Front Panel The PairGain FRC 752 p...

Page 2: ...emote electronics and subscriber terminations The enclosure accepts one common RT Line Unit and up to four Channel Units The Remote Terminal communicates with and is line powered from the COT over two pairs of 19 to 26 gauge 0 9 mm to 0 4mm twisted pair telephone wire Each pair carries both power and HDSL signaling 2 03 HDSL Transmission PG Flex utilizes HDSL transmission technology between the CO...

Page 3: ...t Drive 15 REN maximum per RT 5 REN maximum per channel RT DC Supervisory Range 960 ohms Maximum cable loop resistance minus 430 ohms for handset is 530 ohms RT Idle State Loop Voltage On Hook Greater than 40 V dc Ring is negative with respect to Tip RT Loop Closure Off Hook Detection Less than 960 ohms between Tip and Ring RT On Hook Detection Greater than 10 kohms Operating Temperature Humidity ...

Page 4: ...and regular maintenance PairGain will repair or replace any unit without cost during this period if the unit is found to be defective for any reason other than abuse or improper use or installation 5 02 This module should not be field repaired If it fails replace it with another unit and return the faulty unit to PairGain for repair Any modifications of the unit by anyone other than an authorized ...

Page 5: ...for a prolonged period store the equipment in its original container 9 TURN UP AND TESTING 9 01 Table 2 provides step by step turn up and test procedures for the FRC 752 Channel Unit 10 TROUBLESHOOTING 10 01 Table 3 provides troubleshooting procedures based on indications displayed by the front panel indicators of FRC 752 Channel Unit TABLE 2 FRC 752 RT CHANNEL UNIT TURN UP AND TESTING CAUTION Obs...

Page 6: ...ance shorts on the subscriber drop 2 If ringing isn t present on a circuit terminated on the same RT Channel Unit try ringing a line terminated on another RT Channel Unit If the line rings replace the RT Channel Unit If the line doesn t ring replace the RT Line Unit Phone Doesn t Stop Ringing Faulty subscriber station instrument faulty RT Channel Unit or loop length too long Phone stops ringing wh...

Reviews: