27
GTV
FORCED CONVECTION AIR HEATERS
Instructions for Installation and Servicing
Type
L
GTV-20..58A
1080 mm
GTV-20..27C, CL
1080 mm
GTV-33..58C, CL
1250 mm
27. picture: Fixing points
Cantilever dimensions at GTV 20-58KW appliances:
Cantilever fixing points (GTV-20....58KW)
The cantilever can be mounted to the wall by its fixing points .
(4 pcs/pair)
Take the following into consideration:
•
in case of appliance power up to
max� 58KW
the proposed mounting solution is the using of tightening-wall plug type
M10/100
for cantilever fixing
• in case of cantilever-type fixing solution
above appliance power 58KW
the using of tightening-wall plug is not enough because
of weight of appliance for this reason
it is proposed drilling through of wall and mounting with over-lap�
WARNING! Before installation of appliances between 68-116KW the STATIC investigation of walling
!is in any case needed
Proposed installation mode above 58KW:
•
drilled through wall
with overlap
,
•
mounting of so- called „
resting column
” under the end of cantilever,
•
placing on stand frame
(e.g. in case of prompt structure building),
•
suspension by wire-rope�
The appliance can be mounted on the fixed cantilevers by lengthwise grooves. These grooves make the suitable fixing possible ensuring
the minimum fire protection distances.
The fixing of appliance to the cantilever can be executed by 4 pcs
M8x25 5�6
screws or M8 threaded rod� There are 4-4 pcs riveted M8
nut on top and bottom side of device�
WARNING! During the installation of appliance lockwasher has to be mounted under locknuts,
!threaded rod and screws
Console
M8 screw
Console fixing
points