32
GTV
FORCED CONVECTION AIR HEATERS
Instructions for Installation and Servicing
C52 type
The combustion air supply is across the wall from outside, the flue system is
vertically across the roof to outside with 100 mm pipe� The pipe diam� above
the roof is 150/100 mm�
Components:
•
vertical roof terminal
• flue pipe 250/500/1000 mm ( Ø100 mm)
•
elbow 90° (Ø100 mm)
•
rubber sealing
•
air supply pipe 250/500/1000mm (Ø150 mm)
•
cover
The pipes can be extended or shorted with different components:
•
pipes 250/500/1000 mm ( Ø100 mm)
•
clamps
35. picture: C52-type execution
The combustion air supply and flue system is vertically-coaxial solution- across the
roof to the outside at B22 type.
36. picture: Minimum distances at B22 type
min. 1200
min. 800
min. 800
The minimal distance of the flue and air supply system from the wall at C12K type
37. picture: Minimum distances at C12K type
min. 600
min. 800
min. 600
Minimum distance of the air supply and venting sets