Pakon Part#125307-B

October 10, 2006

1

Scanner Specifications

Minimum Host Computer Specifications

Pentium III or Athlon CPU, 700 MHz or higher, with MMX support

4GB of free hard drive space, capable of a sustained transfer rate of 30MB/sec. If IDE, it must 
either be a 

Primary

 or 

Secondary Master

 drive or connected using a serial ATA connection. 

Windows 2000 and Windows XP

256 MB of RAM

USB 2.0

Screen resolution of 1024x768 or higher

Power

External power supply

15V, 2.4 amps, 

50-60 Hz Input voltage frequency

Plug polarity is plus center, minus outside

5.5mm outer diameter, 2.5mm inner diameter

Contents of Box

F-135 or F-135 Plus Film Scanner

6ft. USB 2.0 Cable

Software and User Manual CD

External power supply and power cord

Size

6.75” x 8.5” x 14.75” (H x W x D)

17.15cm x 21.6cm x 37.5cm (H x W x D)

Resolutions

The F-135 has two supported resolutions: 
4Base    1000 x 1500 
8Base    1500 x 2250

The F-135 Plus has three supported resolutions:
4Base    1000 x 1500 
8Base    1500 x 2250
16Base   2000 x 3000

Summary of Contents for F-135

Page 1: ...F 135 F 135 Plus User Manual...

Page 2: ...Screen resolution of 1024x768 or higher Power External power supply 15V 2 4 amps 50 60 Hz Input voltage frequency Plug polarity is plus center minus outside 5 5mm outer diameter 2 5mm inner diameter C...

Page 3: ...tself Film Types and Variations The F 135 is designed to scan 35 MM color negative film 35 MM cut strips are supported in sizes from 3 frames to 40 frames However to ensure DX code reading the strips...

Page 4: ...not already installed on the PC 2 Clear a space near your computer system to place the F 135 scanner The USB 2 0 cable must be able to reach the PC so it cannot be more than 6 feet 2m from the compute...

Page 5: ...prompt you to click Next to continue the driver installation 8 Then click on Finish to finish the driver installation 9 The process will repeat twice before finishing 10 After the driver is finished i...

Page 6: ...or Maintenance chapter BIOS Configuration The following BIOS options are used on systems configured by Pakon and are recommended to be configured as outlined below Option Setting Plug and Play O S Dis...

Page 7: ...e scanner DX Code up and starting with the lowest number first as shown below Do not attempt to remove film from the scanner while the scanner motor is moving This will cause damage to both the film a...

Page 8: ...s it is recommended to perform the following regularly Clean all customer film with a lint free cloth before scanning it When the scanner is turned off cover it with a plastic or lint free cover Use a...

Page 9: ...resolution We recommend ensuring the film is clean before putting it into the scanner 1 Position the tip of the compressed air hose in the film track entrance and blow moving the hose up and down whi...

Page 10: ...Pakon Part 125307 B October 10 2006 9 2 On the film exit side blow the air away from the film exit...

Page 11: ...ard freight costs both ways for the repaired or replaced unit Any expedited shipping fees are the responsibility of the buyer After Warranty Service OEM Service Scanner Phone Service Incident charge o...

Page 12: ...s not to be unreasonable withheld or 3 to any prod uct on which this serial number or name has been altered defaced or removed This warranty also shall not apply to any Pakon product whose unsatisfact...

Page 13: ...serial number of your scanner If you prefer to email support please include the following information in your email request Any applicable error log files Version number of PSI Serial number of your...

Page 14: ...nce with the instruction manual may cause harmful interference to radio com munications Operation of this equipment in a residential area is likely to cause harmful interfer ence in which case the use...

Page 15: ...Pakon Part 125307 B October 10 2006 16 Shipping and Storage Conditions Temperature 25 to 60 degrees Celsius...

Reviews: