Pakon Part#124603-F
February 24, 2004
12
3. Close the door by pushing the drawer forward until it clicks shut.
In the software interface program, select “APS”.
Calibration
There are two types of calibration for the F-235.
Color calibration is set during the manufacturing process, as well as any service that
involves the CCD or any optical filter. This is to be performed by trained and authorized service
personnel only.
Scanner corrections are performed automatically. They consist of a series of steps per-
formed when the scanner is first turned on, as shown below:
•
Start-up corrections
•
Initial bulb warm-up
•
Gain
and exposure Control Corrections
•
Run
Time Corrections
Format Change
The scanner will automatically change the film guide, lens position, CCD position, or
color filter position whenever one of the following steps take place:
•
Film Format change between 35mm and APS
•
Film type change between color negative, color reversal, and black and white
•
Magnification Change (Change of scanning resolution)
Film Gate Change
The film gate opens and closes depending on the size of the film being scanned. It will
open for 35mm film and close for APS film. This gate will open or close automatically when a
different film size is selected.