17
Document # 106050
© 2019 PalatiumCare, Inc - Rev 1.3.3
Change Keypad Backlight Level
– Passive
The change keypad backlight level
– Passive feature allows you to change the brightness of
the backlight LEDs when the keypad is passive. The keypad goes into passive mode after 10
seconds of no keys being pressed. Please note, the backlight will not turn on when the
keypad is running on battery power. The value can be between 0 and 9 with 9 being the
brightest. 0 will make the backlight turn off. The default value is 9.
To change the keypad backlight level
– passive feature, enter the following sequence in
programming mode:
30 # 7 # VALUE # **
Change REX to Reset Alarms
The change REX to reset alarms feature allows you to configure the keypad to reset alarms
with the REX input. This is useful when you have a 3
rd
party keypad on the other side of the
door connected to the REX input and you want a valid code entry to reset the alarm. A value
of 0 will not allow the REX input to reset an alarm, only grant access through the door. A
value of 1 will allow the REX input to reset an alarm in addition to granting access throught he
door. The default setting is 1.
To change the REX to reset alarms feature, enter the following sequence in programming
mode:
30 # 8 # VALUE # **
Change Radio Monitoring
The change radio monitoring feature allows you to configure the keypad to poll the radio to
ensure the EN1941XS radio module is connected and responding to the keypad. If the radio
module is disconnected, not responding, or a different module is inserted the keypad will start
beeping and flashing the Radio Communication Error pattern until the problem is resolved. If
you are using the EN1941, you must disable radio monitoring. A value of 0 will stop the
keypad from polling for the radio module. A value of 1 will make the keypad poll for the radio
module. The default value is 1.
To change the radio monitor feature, enter the following sequence in programming mode:
30 # 9 # VALUE # **
Change User Code Length
The change user code length feature allows you to change the length of the user codes to
make them more secure. The value can be set between 4 and 6 digits. The default value is 4.
To change the radio monitor feature, enter the following sequence in programming mode:
32 # 4 # VALUE # **
Factory Default Keypad
The factory default keypad feature allows you to set all of the keypad’s configuration settings
back to factory defaults.
To change all of the settings to factory defaults, enter the following sequence in programming
mode:
46 # 00000 # 00000 # **
Learning in the Transmitter
The AIO Keypad is used as a location device in the PalatiumCare system. When learning in
the device, press the reset button (SW2) immediately after clicking the ready button on the UI.