15
translation
3.7 Electric drive, start and emergency stop
The power output of the motor is 7,5 kW at a speed of 1450 r.p.m.
The machine is equipped with an automatic Y-D starter with an emergency stop
feature.
All electric installations must be completed.
In the 380 V-system the fuse size is 16 A slow.
The cross-section of the required extension cord is 2,5 mm2.
Before starting up the machine, check that it rotates in the direction shown by the
arrow at the end of the motor.
Check the direction of rotation by allowing the motor to run for a short while and,
after that, stopping it immediately.
NOTE!
Only skilful professionals are allowed to carry out the electric work
that changing the direction of rotation requires.
Make sure that the extension cord, that you use, is equipped with a switch that
enables changing the direction of rotation of the motor using a screwdriver.
3.8 Starting
Press the start button. In the Y-position the motor starts rotating at slow speed with
low output. The start phase takes several tens of seconds.
As the engine speed increases, the D-position is switched on and the motor quickly
reaches full speed. As the position D is switched on, the signal light between the
start and stop switches illuminates.
NOTE!
The machine must not be operated until the motor has reached full
speed, because in the Y-position the output of the electric motor is very low.
3.9 Emergency stop of an electric-motor-powered machine
The emergency stop is carried out by depressing the Emergency Stop button,
button B on the starter.
The button is reset by pulling it up.
3.10 Starting the electric motor in frost
In severe frost, the hydraulic oil and the oil in the angular gear can become so cold
and viscous or the V-belts so rigid that the motor cannot be started.
If operating the machine under cold conditions, we recommend that less viscous
hydraulic oils be used.
NOTE! A 300 W electric heater carpet with thermostat is available as an option
for the hydraulic oil tank. We recommend using the carpet whenever the
machine is operated under cold conditions. The starter is equipped as standard
with a lever switch for the heater. Keeping the heating switched on for about 1-2
hours is enough to make the oil sufficiently fluent.
Summary of Contents for C700 COMBI
Page 38: ...34 translation 10 ELECTRIC DIAGRAMS ...
Page 39: ...35 translation ...