16
1 INITIAL
CONFIGURATION
Depending on the type of installation, the best con
¿
guration needs to be selected for the stove operation.
Before proceeding, power up the stove using the safety switch on the rear.
a) Use the arrow buttons
to go to the setup menu and then press
;
b) Use the
button to select the password “7” and then press
to con
¿
rm;
c) Use the
buttons to scroll to and select submenu
[30]
; “
--0
” will
À
ash on the display;
d) Press
and enter the value “54” using the
buttons;
e) Press
to con
¿
rm;
f) The current con
¿
guration will be displayed;
g) To change the con
¿
guration, press
and enter the value of the new con
¿
guration using the
buttons;
h) Press
to con
¿
rm.
$IWHU KDYLQJ FKDQJHG WKH FRQ¿JXUDWLRQ D FRPPXQLFDWLRQ HUURU PHVVDJH PD\ EH GLVSOD\HG IRU D IHZ
VHFRQGV,JQRUHWKLVDQGVZLWFKWKHVWRYHRIIXVLQJWKHVDIHW\VZLWFKRQWKHUHDUZDLWDIHZVHFRQGVDQG
VZLWFKLWEDFNRQ
TWO DIFFERENT CONFIGURATIONS ARE AVAILABLE:
&21),*85$7,21GHIDXOW
Set this con
¿
guration to switch the stove on or off manually or in programmed mode.
The stove will module its power according to the room temperature read by the probe on the stove.
,WLVSRVVLEOHWRVHWWKHIXQFWLRQ³(FRPRGH´WRDOORZWKHVWRYHVZLWFKRQRURIIDFFRUGLQJWRWKHVHW
WHPSHUDWXUH
In this con
¿
guration it is possible to set also the antifreeze function.
CONFIGURATION 2
Set this con
¿
guration when the stove is controlled by an external thermostat
or timer thermostat).
,QWKLVFRQ¿JXUDWLRQWKHVWRYHVZLWFKHVRIIZKHQUHDFKLQJWKHH[WHUQDOWKHUPRVWDWVHWWLQJ
In this con
¿
guration it is not possible to set also the antifreeze function.
CONNECTION TO AN EXTERNAL TIMER THERMOSTAT
The stove can be connected to an external timer thermostat that switches the stove on or off according to the
set temperature.
When the set temperature is reached the thermostat opens the circuit and consequently switches off the stove.
The external thermostat is connected to the two terminals on the board of the stove, which are jumpered in the
factory. Disconnect the jumper and connect the two thermostat contacts.
The stove must be set to con
¿
guration 2 following the instructions shown in the paragraph on “Initial con
¿
guration”.
After
¿
rst installing the timer thermostat, the stove needs to be switched on manually, while the timer thermostat is
in “call” status. This operation is also required in the event of power failures or if the stove is switched off manually.
To avoid overlapping the working time bands, it’s recommend to disable
set to OFF) the stove’s timer.