58
USE AND & MAINTENANCE
13 PROBLEMS, CAUSES AND SOLUTIONS
Attention, for maintenance operations it is mandatory to use only and exclusively genuine spare parts.
PROBLEM
CAUSE
SOLUTION
Pellets are not inserted into
the burn pot
1) The hopper is empty.
2)
7KHÀXHJDVH[WUDFWLRQDVSLUDWRUGRHVQRWZRUN
3)
7KHIHHGVFUHZLVEORFNHGE\IRUHLJQREMHFWV
4) The control panel is without current.
5)
7KHÀXHLVEORFNHGDQGGRHVQWDOORZWKHGLIIHUHQWLDO
pressure switch.
1) Fill the hopper.
2) Call customer service.
3) Call customer service.
4) Check the correct insertion of the plug and
the operation of the fuses.
5)
&OHDQWKHZKROHVHFWLRQRIWKHÀXHJDV
SLSHDQG¿UHSODFH
At ignition the boiler is
working for a few minutes
and then goes off in safety.
The exhaust gases do not reach the minimum temperature
for turning of the ignition
Make sure the burn pot is clean
7KH¿UHEXUQVZLWKDVPRN\
ÀDPH
1) Inadequate combustion air as the ventilation holes in
the burn pot are clogged.
2) Flue clogged or blocked.
3) Boiler with a dirty heat exchanger.
4) Poor quality pellets or with too much moisture.
1) Clean the burn pot.
2)
&OHDQWKHÀXHJDVSLSHDQGWKH¿UHSODFH
3) Clean the heat exchanger.
4) Replace the pellet.
7KHÀDPHGRHVQRWWXUQRQ
1) Air inlet clogged.
2) Presence of ashes in the burn pot.
3) No more pellets.
4) The differential pressure switch tripped.
1) Check that the air inlet is clean.
2) Clean the burn pot.
3) Fill the hopper.
4)
&OHDQWKHÀXHJDVSLSHDQGWKH¿UHSODFH
Pellet loader blocked.
The use of poor quality pellets, the accidental introduction
of sawdust or the accidental deposit of pellets which
obstruct the burner feed chute, can lead to blocking of
the feed screw.
Often to solve the problem, without the
LQWHUYHQWLRQRIWKHVHUYLFHFHQWUHLWLVVXI¿FLHQW
WRLQWURGXFHDÀH[LEOHVWHHOURGLQVLGHWKHSHOOHW
drop tube from inside the combustion chamber
when the boiler is off and cool and remove the
blocked pellets making them fall inside the burn
pot until the feed screw is completely released.
This operation should be
carried out when the boiler
is off, after removing the plug
from the power supply.
1) Air exchanger fan dirty
2) Breakdown of the air exchanger fan
3) Boiler over temperature with safety thermostat
activation
4) Flue clogged or wind shields with clogged net
1) Call customer service
2) Call customer service
3) Call customer service
4)
&OHDQWKHFRPSOHWHÀXHUHPRYHWKHZLQG
shields with net
Repetitive activation of the
safety thermostat
1) Air exchanger fan dirty
2) Breakdown of the air exchanger fan
3) Check the cleanliness of the boiler
1) Call customer service
2) Call customer service
3) Call customer service
Repetitive activation of the
water safety thermostat
1) Burn pot not clean
2) Internal circulator block (internal pump)
3) Internal circulator failure
1) Clean the burn pot and the inside of the
chamber
2) Unblock the internal circulator
1) Call customer service
If you are not able to resolve the problem please contact the Authorized Service Centre or your local dealer.