32
5.9 INITIAL
CONFIGURATION
'HSHQGLQJRQWKHW\SHRILQVWDOODWLRQWKHEHVWFRQ¿JXUDWLRQQHHGVWREHVHOHFWHGIRUVWRYHRSHUDWLRQ
Before proceeding, power up the stove.
Use the arrow buttons to scroll between the icons until reaching the setup menu
;
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
WRFRQ¿UP
c) Use the
buttons to scroll to and select submenu
[30]
; “
--0
´ZLOOÀDVKRQWKHGLVSOD\
d) Press
and enter the value “54” using the
buttons;
e) Press
WRFRQ¿UP
f)
7KHFXUUHQWFRQ¿JXUDWLRQZLOOEHGLVSOD\HG
g)
7RFKDQJHWKHFRQ¿JXUDWLRQSUHVV DQGHQWHUWKHYDOXHRIWKHQHZFRQ¿JXUDWLRQXVLQJWKH
buttons;
h) Press
WRFRQ¿UP
$IWHUKDYLQJFKDQJHGWKHFRQ¿JXUDWLRQDFRPPXQLFDWLRQHUURUPHVVDJHPD\EHGLVSOD\HGIRUDIHZ
seconds. Ignore this and switch the stove off using the safety switch on the rear, wait a few seconds
and switch it back on.
FIVE
DIFFERENT
CONFIGURATIONS
ARE
AVAILABLE:
CONFIGURATION
1
6HWWKLVFRQ¿JXUDWLRQZKHQWKHVWRYHLVFRQWUROOHGE\DQH[WHUQDOWKHUPRVWDWRUWLPHUWKHUPRVWDW
7KLVFRQ¿JXUDWLRQFDQDOVREHXVHGWRVZLWFKWKHVWRYHRQRURIIPDQXDOO\RUE\WLPHUZLWKRXWXVLQJDQH[WHUQDO
thermostat, but rather leaving the two terminals jumpered as per the factory setting.
,QWKLVFRQ¿JXUDWLRQWKHVWRYHVZLWFKHVRIIZKHQUHDFKLQJWKHH[WHUQDOWKHUPRVWDWVHWWLQJRUDOWHUQDWLYHO\
modulates output (to minimise fuel consumption) when reaching the set water temperature.
The stove will turn off also in case the water temperature continues to rise despite the modulation. In this case,
the stove will turn on only if the temperature difference between the value you set up and the real one is higher
than 20°C.
,QWKLVFRQ¿JXUDWLRQLWLVWKHUHIRUHUHFRPPHQGHGWRUHJXODWHDKLJKZDWHUWHPSHUDWXUHH[&
CONFIGURATION
2
6HWWKLVFRQ¿JXUDWLRQWRVZLWFKWKHVWRYHRQRURIIPDQXDOO\RUE\WLPHUZKHQWKHVWRYHLVFRQQHFWHGGLUHFWO\WR
the central heating radiators.
The stove will modulate output according to the room temperature read by the probe on the stove.
The “Eco-mode” function can be used to have the stove switch off or on based on the set room temperature.
7KHIURVWSURWHFWLRQIXQFWLRQFDQDOVREHVHWLQWKLVFRQ¿JXUDWLRQ
CONFIGURATION
3
6HWWKLVFRQ¿JXUDWLRQZKHQZDQWLQJWRFRQQHFWWKHVWRYHWRDVWRUDJHWDQNZLWKFRLO
The stove will be controlled (switch on and off) based on the temperature read by the probe in the storage tank.
7KHIURVWSURWHFWLRQIXQFWLRQFDQDOVREHVHWLQWKLVFRQ¿JXUDWLRQ
CONFIGURATION
4
6HWWKLVFRQ¿JXUDWLRQZKHQZDQWLQJWRFRQQHFWWKHVWRYHWRDVWRUDJHWDQNZLWKRXWFRLO
The stove will switch on based on the temperature read by the probe in the storage tank, and will switch off
based on the stove return temperature.
7KHIURVWSURWHFWLRQIXQFWLRQFDQDOVREHVHWLQWKLVFRQ¿JXUDWLRQ
CONFIGURATION 5
6HWWKLVFRQ¿JXUDWLRQRQO\LQFRQMXQFWLRQZLWKWKH³(YHUVSULQJ´V\VWHP
The stove will regulate the power according to the ambient temperature read by the sensor on the “Everspring”
system. It will also be possible to handle various levels of ventilation of “Everspring” directly from the stove.