ECOFIRE HOTTY
cod. 004770300 - 09/2008
49/64
GB
D
7.7.7 Alarm ALar hot (smoke over temperature
alarm)
This occurs when the smoke probe detects too high
temperature.
7.7.8 Alarm ALar FirE (shut down during
operations alarm)
This occurs during operations if the flame goes out
and the smoke temperature drops under the minimum
operating threshold.
The shut down procedure is immediately initiated.
7.7.9 Alarm ALar Sic (main thermostat alarm)
This occurs if the main safety thermostat reads a
temperature over the permitted one.
Message “
ALar Sic
” is displayed and the system is
stopped.
7.8
CLEAN GRATE
“CLEAN GRATE” mode may be activated, at set
intervals, during normal operations.
Message “
StoP FirE
” is displayed.
7.7.7 Alarm ALar hot (Alarm
Rauchübertemperatur)
Tritt auf, wenn der Rauchfühler eine zu hohe
Temperatur ermittelt.
7.7.8 Alarm ALar FirE (Abschaltalarm während der
Betriebsphase)
Tritt während der Betriebsphase auf, wenn die
Flamme verlischt und die Rauchtemperatur unter die
minimale Betriebsgrenze sinkt.
Dabei wird unverzüglich der Ausschaltvorgang
eingeleitet.
7.7.9 Alarm ALar Sic (Alarm Hauptthermostat)
Tritt auf, wenn das Sicherheitsthermostat eine höhere
Temperatur als zulässig ermittelt.
Es erscheint die Meldung “
ALar Sic
” und das System
wird angehalten.
7.8
REINIGUNG DES GLUTBECKENS
Es kann dazu kommen, dass während des normalen
Betriebs im Betriebsmodus in festgelegten Abständen
der Modus “REINIGUNGGLUTBECKEN” ausgelöst
wird.
Es wird die Meldung “
StoP FirE
” angezeigt.