ECOFIRE ALICE / BARBARA
cod. 004770900 - 10/2010
37/96
GB
D
6.2.2 External connections
Where available, on the upright of the stove are installed
(Fig. 6.2.2-1):
O/O
= Free 1 - 2
TE
= External thermostat 3 - 4
RS232
= Palazzetti serial connection for internal use
6.2.2.1 Thermostat connection
THERMOSTAT CONNECTION TERMINAL BLOCK
(Fig. 6.2.2.1-1)
If a thermostat is used it has to be connected to the
terminal block at the back of the stove, following the
diagram given in Fig. 6.2.2.1-1.
Room thermostat (N.C.= Normally Closed)
If an external thermostat, whose contact opens, is
connected to the board, the stove will set itself on
“
REMOTE STAND-BY
”. See chapter 7.6.5.
O
Disconnect the mains power supply before
proceeding with connections.
The room thermostat must be the free contact type.
(There must be no output voltage).
6.2.2 Externe Anschlüsse
Wenn vorgesehen, am Ständer des Ofens befinden sich
(Abb. 6.2.2-1):
O/O
= Frei 1 - 2
TE
= Außenthermostat 3 - 4
RS232
= Serieller Anschluss zum internen Gebrauchs
Palazzettis
6.2.2.1 Thermostat-Anschluss
KLEMMLEISTE THERMOSTATANSCHLÜSSE (Abb.
6.2.2.1-1)
Die Anschluss eines eventuellen Thermostats muß an
der eigens dafür bestimmten, an der Rückseite des
Heizofens angebrachten Klemmleiste erfolgen,
entsprechend dem in der Abb. 6.2.2.1-1 gezeigten
Schaltplan.
Raumthermostat
(N.C.= Normalerweise
geschlossen)
Wenn an der Karte ein Außenthermostat
angeschlossen ist, dessen Kontakt sich öffnet, geht der
Heizofen in “
STAND-BY REMOTO
” über. Siehe Kap.
7.6.5.
O
Vor Durchführung der Anschlüsse, die
Stromversorgung unterbrechen.
Das Raumthermostat muss einen freien Kontakt
haben.