94
004778982 - 09/08/2022
10 CLEANING AND MAINTENANCE
Cleaning can be carried out by the user.
Maintenance operations must be performed by an authorised technical assistance centre.
Before performing any maintenance operation, take the following precautions:
• Ensure that all appliance parts are cold.
• Make sure that the ashes are completely extinguished.
• Use personal protective equipment provided for by Directive 89/391/EEC.
• Make sure that the general line switch is turned off.
• Make sure that the power supply cannot be accidentally reactivated. Remove the plug from the wall
socket.
• Always use appropriate equipment for maintenance.
• Once maintenance or repair operations have been completed, before putting the appliance back
into service, reinstall all the safety guards and reactivate all the safety devices.
10.1 Routine maintenance cleaning schedule
10.1.1 Routine cleaning (User)
EVERY TIME THE
APPLIANCE IS
TURNED ON
EVERY
WEEK
Burn pot (
Fig. 56
)
X
Ash drawer/compartment (
Fig. 56
)
X
Glass (
Fig. 57
)
X
10.1.2 Ordinary maintenance (certified technical service centre)
1 YEAR (*)
Door and burn pot seals
X
Smoke collector (
Fig. 58
)
X
Door safety (
Fig. 59
)
X
Flue gas system (
"10.3.3 Maintenance of the smoke system" on
page 96
)
X
Device (
"10.3.5 Appliance maintenance" on page 97
)
X
(*) At least once a year or every 4000 kg of pellets burned.