66
004778610 - 16/12/2020
WT60 3D V16 EPLUS
004726709 - 24/11/2020
NOTE:phase protection,added by customer.Do not change polarity!
UI
POWER
IN
GREEN
BR
OWN
+5V
GND
485A
485B
J17
J13
J2
J18
J19
J20
J10
J14
J1
YELL
OW
BR
OWN
WHITE
K
K
RED
RED
GREEN
GREEN
BL
UE
Air
BR
OWN
GREEN
BR
OWN
RED
WHITE
BLUE
1
2
3
USER INTERFACE
5
6
BROWN
WHITE
GREEN
YELLOW
4
7
Fig. 8
1
Flue gas probe
2
Combustion chamber temperature
probe
3
Door motor
Air
4
Room fan
5
Limit switch for combustion air
control
6
Motorised door limit switch
7
Room temperature probe
Control panel
In configuration 2 component no.3 (room
sensor) will be converted into a room thermostat
input, which will control the shutdown of the
stove.