86
004778610 - 16/12/2020
11 CLEANING AND MAINTENANCE
Maintenance operations must be performed by an authorised technical assistance centre.
Before performing any maintenance operation, take the following precautions:
• Ensure that all appliance parts are cold.
• Make sure that the ashes are completely extinguished.
• Use personal protective equipment provided for by Directive 89/391/EEC.
• Make sure that the main line switch is disconnected (for versions V16 and V16eplus).
• Make sure that the power supply cannot be accidentally reactivated. Remove the plug from the
wall socket (for versions V16 and V16eplus).
• Always use appropriate equipment for maintenance.
• Once maintenance or repair operations have been completed, before putting the appliance back
into service, reinstall all the safety guards and reactivate all the safety devices.
11.1 Maintenance of the smoke system
To be carried out at least once a year, or every 4 tonnes of fuel burned (as specified in the product
standard), by contacting specialist personnel
If there are horizontal sections, it is necessary to check and remove any deposits of ash and soot
before they obstruct the passage of fumes.
The incrustations inside the flue affect the optimum forced draught. When they reach a thickness of
5-6 mm, with high temperatures and sparks, they can ignite with easily imaginable consequences
both for the flue and for the house.
11.2 Appliance maintenance
To be carried out at least once a year, or every time the appliance signals maintenance request.
During the maintenance operation, the technician must:
• clean the flue gas transit area thoroughly and completely;
• check the condition and tightness of all the seals;
• check the condition of all internal components and make sure they are clean;
• make sure the flue gas outlet connection is sealed and clean;
• check the correct operation of the appliance.