23
00 477 7300- 18/02/2019 - PALAZZETTI - PN - Italy
ENGLISH
3 Handling and Transport
We recommend to unpack the stove only when it is
reached the place of installation.
Pay attention to overbalancing.
During lifting avoid jerking or abrupt movements.
Make sure that the lifting carriage has a payload higher
than the weight of the appliance to be lifted. The
responsibility of the lifting of loads lies on the person
handling the lifting equipment.
Make sure that children do not play with the components
of the package (e.g. films and polystyrene). Suffocation
hazard!
4 Fuel type
The stove should preferably be fuelled with well seasoned
beech/birch wood or with wood briquettes in commercial
sizes of 25 or 33 cm.
The maximum humidity must be 25%.
The recommended quantity of wood is indicated in the
technical data table.
Each type of wood has different characteristics that also
affect the combustion efficiency.
It is prohibited to burn: waste, bark, wood treated with
paints, panels, coal, plastic materials; in these cases the
warranty of the appliance is voided.
Even if the burden to check the characteristics of the
wood chosen is on the user, we specify that:
•
The use of conifers (pine-fir) is discouraged: they
contain high quantities of resinous substances that
quickly clog the flue.
•
IMPORTANT: the use of wood particularly rich of
aromatic oils (e.g. eucalyptus, myrtle, etc.) causes
the sudden deterioration of the internal components
of the product.
We would like to remind the customer that any damage to
the product or its components due to external elements,
is not covered by the warranty and therefore nothing can
be requested to the Manufacturer.
The nominal yield declared in kW of the stove, is obtained
by burning a correct quantity of wood, being careful not
to overload the combustion chamber.
Overloading of the stove can lead to a damage or
deformation of the product itself.
The reference standard for the fuel is the UNI EN ISO
17225-5 “specifications and classification for firewood”.