19
x
y
[P
\P
[\P
- 6.1 -
- 6.2 -
- 6.3a -
- 6.3b -
ENGLISH
6.4
CONNECTION TO FLUE PIPE
'LPHQVLRQLQJWKHÀXHPXVWEHH[HFXWHGLQDFFRUGDQFH
with EN 13384-1.
The
SMOKE
FRQQHFWLRQEHWZHHQWKHVWRYHDQGÀXH
should have the same cross section as the stove’s smoke
RXWOHW7KHVPRNH¿WWLQJPXVWEHVHDOHGDQGWKHXVHRI
ÀH[LEOHPHWDOOLFSLSHVLVSURKLELWHG
In order to connect the stove to the chimney you may
perform maximum 3 changes of direction that should not
exceed 90°, the fume duct should not exceed 2 metres
in length and 3 metres in total (- 6.1 -).
if the outlet is placed on the ceiling, make sure that the
¿UVWYHUWLFDOVHFWLRQKDVDWOHDVWFPEHIRUHFKDQJLQJ
the direction.
Follow the indications in the technical data sheet
regarding the chimney draught value.
6.5
AIR INTAKE CONNECTION
It is necessary to provide an external air intake to
HQVXUHWKHÀRZRIFRPEXVWLRQDLUWRWKHVWRYH
(-6.2-).
The dimensions of the hole must comply with the values
set forth in the table of technical data shown in the
“Product booklet”.
According to local standards in force, air intake could be
taken directly from the room (- 6.3a -) or connected to
the stove (- 6.3b -).
To get the air directly from the outside, you must install
the connection for the combustion air, on the back of
the stove, after cutting the pretrimmed on the rear of
the stove.
Is forbidden the intake of air for combustion from
JDUDJHVURRPVZKHUHÀDPPDEOHPDWHULDOVDUHVWRUHG
RUZKHUHWKHUHLVGDQJHURI¿UH
.
The combustion air intake should be protected by
an anti-insect grille and placed where it can not be
accidentally obstructed, and made in such a way that the
useful cross-section allows the right amount of oxygen
to reach the stove.
In the room where the stove is located, if there are one
or more extraction fans (exhaust hoods and the like),
there may be problems with combustion due to lack of
combustion air.