56
004778740 - 14/06/2021
4.3 Technical features
A70 AC70
AC70
A70
Min
Max
Min
Max
Overall thermal power (output)
kcal/h
2493
7739
2493
7739
kW
2.9
9
2.9
9
Yield
%
94.5
90.7
94.5
90.7
Flue gas temperature
°C
64.9
124.4
64.9
124.4
Flue gas flow rate
g/s
4.13
8.8
4.13
8.8
Hourly fuel consumption
kg/h
0.643
2.05
0.643
2.05
CO emissions (at 13% of O2)
mg/
Nm
3
360
127
360
127
Flue gas outlet
mm
Ø 80
Outside air intake
mm
Ø 60
Fuel
Wooden pellets
Flue draught
Pa
12 (±2)
Minimum draught for chimney sizing
Pa
0.0
Appliance suitable for rooms no smaller than
m
3
30
30
Feeding tank capacity
kg
15
Weight
kg
110
Electrical data
AC70
A70
Voltage
V
230
Frequency
Hz
50
Max power absorbed during operation
W
115
Power absorbed at electric ignition
W
330