• Open the door, insert the Allen key (1) in the
stop release seat; turn the locking lever clock-
wise to position (2) to lock the guides
1
2
Fig. 28
Fig. 27
• Close the door
7.3 Assembly diagram
A)
For correct installation, all the joints of the
smoke ducting between the fireplace and the
flue must be sealed.
B)
Rear external air intake, ensure a minimum
distance of 5 cm between cladding and com-
bustion air intake pipe.
C)
UNI standards require the installation of a
heat recovery grille as close as possible to the
ceiling.
D)
Counter-hood and fireproof load-bearing
structure
E)
Cladding in ceramic fibre or rock wool with ex-
ternal aluminium foil
F)
Protect any wooden parts with fireproof
material.
G)
Min distance. 1 cm between cladding and fire-
place stove
H)
The cladding must be made of fireproof
material.
A
B
C
D
E
F
G
H
Fig. 29