70
004778740 - 14/06/2021
7.6 Electrical connection
Simply connect the appliance to the electrical
system using the supplied plug (
Fig. 36
).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-
cian in order to prevent any risk.
Fig. 36
It is mandatory that the system is
equipped with an earth connection
and a differential switch in compliance
with the laws in force.
The flue gas evacuation duct must
be equipped with its own earth
connection.
7.6.1 Installation of the control panel
The control panel of the appliance can be applied
to the wall.
Fig. 37
Do not install the recessed box on hot
areas of the hood.
Arrange the passage of the cable be-
tween the panel and the electronic
board, so that it is not damaged by the
high temperature during normal oper-
ation of the appliance.
Connect the cable between the terminals of the
electronic board and the control panel before
closing the boxes.
7.6.2 Connection to the room thermostat
The appliance can be connected to an external
thermostat or chronothermostat that switches it
on and off.
For the connection, refer to the wiring diagram in
the technical specifications.