4.3 Technical features
A78/AC78
A78/AC78
Min
Max
Overall thermal power (output)
kw
3,5
12,5
Yield
%
90,2
87,1
Flue gas temperature
°C
92,4
212,8
Flue gas flow rate
g/s
5,1
8,1
Hourly fuel consumption
kg/h
0,8
2,95
CO emissions (at 13% of O2)
mg/
Nm
3
164
115
Flue gas outlet
mm
Ø 80
Combustion air inlet
mm
Ø 42
External air intake
mm
Ø 110
Fuel
Wooden pellets
Flue draught
Pa
0,0
Minimum draught for chimney sizing
Pa
12±2
Appliance suitable for rooms no smaller than
m
3
40
Feeding tank capacity
kg
110
Weight
kg
23
Electrical data
A78/AC78
Voltage
V
230
Frequency
Hz
50
Max power absorbed during operation
W
91
Power absorbed at electric ignition
W
350