56
004778930 - 06/12/2021
9 PoWER on
• Open the sliding door using the dedicated
glove supplied, gripping the handle and push-
ing it upwards.
• Using the supplied glove, open the primary air
regulator (
A
) to its maximum (
+
) (
Fig. 25
).
• Carefully place the pieces of wood on the fire
box grate (
b
) (
Fig. 25
).
• Place a natural fire-igniter on the pile of wood.
• Add small pieces of wood on top of the stack in
a crossed over-type pattern.
• Light the fire-igniter from above.
• Close the fire door and make sure it is firmly
closed.
• Keep the air regulator (
A
) open to ensure a
high, bright flame.
• Reduce the opening of the air intake (
-
) only
when a good foundation of embers has formed.
-
+
B
A
Fig. 25
9.1 Adding fuel
During operation, to add fuel, it is necessary to
follow this procedure:
• Open the fire door slowly in order to avoid
smoke escaping into the room (depending on
the draught in the flue).
• Refill the fire box with fuel and then close the
fire door.
Do not overheat the product by inserting an
excess quantity of fuel.
Introduce fuel when the embers have formed
and the flame has lowered.
The appliance is equipped with a bypass valve,
which, when opened, facilitates the escape of
smoke into the flue, minimising puffs of smoke
into the environment.
9.2 operation
Natural convection heating.
Combustion is adjusted using the air regulator.
Turning it toward the symbols (
+
) or (
-
) a higher
or lower flow of combustion air will be obtained
and consequently a faster or slower combustion
will result.
-
+
Fig. 26