TERMOPALEX 92-116
cod. 004770440 - 04/2009
45/72
GB
D
5.4
ACCESSORIES
5.4.1 Equipped
TERMOPALEX 92-116 comes with a few accessories
to facilitate its installation and also so that the plumber
can do his job in compliance with current standards.
V.S. = Safety Valve DN ½” (example Fig. 5.4.1.1)
This accessory should be installed by positioning it so
that it can be inspected through a hatch which must be
provided on the external fireplace cladding. The V.S. drain
must be externally connected with a drainpipe which
drains into the sewer.
• The V.S., calibrated at 2.5 bar, must be included even
if the heating fireplace is installed with the open type
expansion tank. In fact, its function is to avoid the boiler
body from exceeding the test pressure should the fill-
up pipe burst due to nighttime freezing, or the safety
pipes for the expansion tanks if they are installed under
the roof and are not lagged and subject to
temperatures below zero.
5.4
ZUBEHÖR
5.4.1 Gehört zum Lieferumfang
Der TERMOPALEX 92-116 wird mit einigen
Zusatzteilen geliefert, sodass die Installation
erleichtert wird und der Installateur die Montage
gemäß den gültigen Gesetzen vornimmt.
V.S. = Sicherheitsventil DN ½” (Beispiel Abb. 5.4.1.1)
Dieses Zubehörteil muss so installiert werden , dass
es über eine vorzusehenden Klappe auf der äußeren
Verkleidung des Heizkamins einsehbar ist. Der Ablauf
des Ablaufventils muss im Freien an einen
Abflusskanal angeschlossen werden.
• La V.S. Das Sicherheitsventil ist auf 2,5 bar eingestellt
und muss auch dann installiert werden, wenn der
Heizkamin mit einem offenen Ausdehnungsgefäß
ausgestattet ist. Das Ventil verhindert bei Zufrieren
der Zulaufleitungen bzw. der am Dachstuhl, nicht
isoliert verlegten, d.h. niedrigen Temperaturen
ausgesetzten Sicherheitsleitungen für
Ausdehnungsgefäße, dass im Kesselkörper der
Prüfdruck überschritten wird.