4.3 Technical features
IDRO V
IDRO V15
IDRO V20
IDRO V24
Min
Max
Min
Max
Min
Max
Overall thermal power (output) kW
6.7
15.2
6.7
20.4
6.7
23.8
Thermal power to water
kW
5.4
14.2
5.4
19
5.4
22.2
Yield
%
95.3
95
95.3
94.8
95.3
94.7
Flue gas temperature
°C
63.5
90.4
63.5
101.5
63.5
108.9
Flue gas flow rate
g/s
7.6
10.98
7.6
12.68
7.6
13.8
Hourly fuel consumption
kg/h
1.49
3.4
1.49
4.57
1.49
5.34
Emissions of CO (at 13% of O2)
mg/
Nm
3
299
56
299
54
299
53
Flue gas outlet
mm
Ø 80
Ø 80
Ø 80
Combustion air inlet
mm
Ø 60
Ø 60
Ø 60
Outside air intake
cm
2
80
80
80
Fuel
Wooden pellets
Wooden pellets
Wooden pellets
Flue draught
Pa
12
12
12
Minimum draught for chimney
sizing
Pa
0
0
0
Stove suitable for rooms no
smaller than
m
3
15
15
15
Feeding tank capacity
kg
45
45
45
Weight
kg
340
340
340
No. of room fans
no.
1
1
1
Room fan flow rate
m
3
/h
320
320
320
Maximum operating pressure
bar
2.5
2.5
2.5
Water content in the boiler
litres
40
40
40
Electrical data
IDRO V15
IDRO V20
IDRO V24
Voltage
V
230
230
230
Frequency
Hz
50
50
50
Max power absorbed during
operation
W
30
30
30
Power absorbed at electric
ignition
W
330
330
330