• Then remove the screws
(B)
, access the inner
chamber and vacuum any residues.
B
Fig. 56
• Remove the screws
(C)
and remove the covers
to access the manifolds (
Fig. 57
)
C
Fig. 57
• Use a flexible brush to clean the exchanger
pipes in the combustion chamber (
Fig. 58
)
• Remove any residues that fall in the flue mani-
fold using an ash vacuum.
Fig. 58
Vacuum the residual ash
Fig. 59
.
Fig. 59
• Re-fit all the components in reverse order.
• Check the condition and tightness of all the
seals.
• Check the condition of all internal components
and make sure they are clean.
• Make sure the flue gas outlet connection is
sealed and clean.
• Remove any deposits of pellet residues in the
hopper.
• Check the correct operation of the appliance.
• Reset any warnings or alarms (the manual re-
set thermostats are on the rear of the appliance
near the power cable).