ENGLISH
5 ALARM
MANAGEMENT
If a malfunction occurs, the following procedure is activated:
1. audible alarm (beep);
2. one of the following system LEDs come on:
;
3. if the problem concerns an error, the stove will switch off.
Pressing and holding the “cancel” button
shows the error code on the display:
(5525
WARNING CODE
DESCRIPTION
POSSIBLE CAUSES
LED
E
1
Faulty control panel
Control panel fault
E
2
Remote control signal communication error
Control panel fault
E
4
Communication error
Connection cable between board and control panel interrupted
or detached.
If this appears when changing con
¿
guration, ignore the error
E1
1
Failed ignition error
Outlet water temperature too high
No pellets; Pellet quality; Faulty ignition system; Burn pot dirty;
Problems with the heating system; Problems with the pump
E1
5
Temperature probe malfunction
Faulty return water temperature probe
E1
6
Temperature probe malfunction
Faulty buffer tank temperature probe
E1
*
Safety error
Door or loading hatch open
E1
**
Thermal safety
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
E1
9*
Incorrect pressure or thermal cutout
Flue system dirty; Seals worn; Insuf
¿
cient combustion air; Heating
system malfunction; Circulation pump malfunction; Pellet tank
overheating
E1
9**
Pressure error
Flue gas exhaust system dirty
Seal gaskets worn
Insuf
¿
cient combustion air
E11
Temperature probe malfunction
Faulty outlet water temperature probe
Faulty air temperature probe
E111
Flue gas temperature probe malfunction
Faulty
À
ue gas temperature probe
A
1
Low pellet level
LFRQÀDVKLQJ
Pellets running out
A
2
Scheduled maintenance warning
(icons
ÀDVKLQJ
The stove periodically requires maintenance to be performed by
a quali
¿
ed technician
A
7
Pressure sensor malfunction
LFRQÀDVKLQJ
Pressure sensor or board fault.
----
Clean stove
Combustion chamber, burn pot or
À
ue gas exhaust system dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
----
Failed ignition error
No pellets; Faulty ignition heater; Worn gaskets; Incorrect burn
pot position
* Only in the stoves equipped with micro safety-switches on the
¿
rebox door and on the pellet hopper lid.
** Only in the stoves without micro safety-switches on the
¿
rebox door and on the pellet hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/off button
for a few moments.
If the error code is “E108 or E109”, before resetting the alarm, manually reset the thermostat located on the rear of the
VWRYH)LJ
Then the stove can be started again.
Before proceeding with a new ignition, check that:
•
the stove has cooled
•
the burning pot is clean and free of any ash residue or pellet
•
the burning pot is correctly positioned in its seat
•
the doors of the hearth and the tank are perfectly closed
Fig.5.1