7 HOT AIR INTAKE CONNECTION.
7.1 HOOD LINER FITTING FOR HEATING IN A SINGLE ENVIRONMENT
Fix the vents at the desired points. The vents are fixed on the hood or on a wall at a height of at least 1,8/2 m from the floor
in order to prevent that the outgoing hot air invests people.
Take the hose ends and lengthen it accompanying it with a rotary movement (fig.7).
Secure the tube(1) to the collars (3) with the clamps (2) (Fig.7.1).
7.2 CHANNELLED PIPELINES FITTING FOR HEATING IN MULTIPLE ENVIRONMENTS
For the heating of multiple environments it is possible to realize ducts according to the indicative schemes in figure 7.2 A-B
Installing one or more vents in the same room as the fireplace and/or in other rooms of the house provides a calculation of
the air distribution which can be done by one of your technician of confidence.
For all the solutions the pipes must always be insulated with insulating material.
The fan outlet vents must not be closed during the operation of the fireplace.
cod. 004777090 MBL - 19/12/2018 - Palazzetti - PN - Italy