TERMINALS CAPACITY 

CAPACITA’ DI CONNESSIONE DEI MORSETTI 

Type 

Tipo 

Minimumcross-sectional area 

Minima sezione 

[mm

2

Maximum cross-sectional area 

Massima sezione 

[mm

2

Internal hearting terminal 

Terminale terra interna 

 

CABLE GLAND /BLANKING ELEMENT TECHNICAL DATA: TIGHTENING TORQUE 

DATI TECNICI PRESSACAVI E TAPPI: COPPIA SERRAGGIO 

Application  

Applicazione 

Minimum tightening torque 

Minima coppia di serraggio

 

[Nm] 

Maximum tightening torque 

Massima coppia di serraggio

 

[Nm] 

Cable gland mounting M16x1,5 

Pressacavo M16x1,5 (montaggio) 

1,5 

ND 

Cable gland mounting M20x1,5 

Pressacavo M20x1,5 (montaggio) 

2,5 

ND 

Cable gland mounting M25x1,5 

Pressacavo M25x1,5 (montaggio) 

4,2 

ND 

Cable gland mounting M32x1,5 

Pressacavo M32x1,5 (montaggio) 

12 

ND 

Cable gland mounting M40x1,5 

Pressacavo M40x1,5 (montaggio) 

ND 

Cable gland on cable M16x1,5 

Pressacavo M16x1,5 (su cavo) 

2,5 

ND 

Cable gland on cable M20x1,5 

Pressacavo M20x1,5 (su cavo) 

3,5 

ND 

Cable gland on cable M25x1,5 

Pressacavo M25x1,5 (su cavo) 

ND 

Cable gland on cable M32x1,5 

Pressacavo M32x1,5 (su cavo) 

8,5 

ND 

Cable gland on cable M40x1,5 

Pressacavo M40x1,5 (su cavo) 

10 

ND 

 

The equipment shall be installed according to this instructions. 

This equipment is intended for fixed installing. 

It shall be installed in vertical position. 

L’apparecchiatura deve essere installata conformemente alle presenti 

istruzioni. 

L’apparecchiatura è intesa per installazione fissa e deve essere 

installata in posizione verticale. 

 

3. 

OVERALL DIMENSIONS AND MOUNTING POSITIONS  

INGOMBRI E POSIZIONI DI  MONTAGGIO  

 

 

External Dimensions

 

Dimensioni esterne 

(mm) 

(mm) 

(mm) 

125x125x113 

110 

110 

252x125x113 

237 

110 

 

 

FASTENERS TECHNICAL DATAup to diameter M6(EQUIPMENT) 

DATI TECNICI DEI FILETTI fino a M6 (APPARECCHIATURA) 

Type of screw 

Tipo di filetto 

Minimum tightening torque 

Minima coppia di serraggio 

[Nm] 

M4 

M5 

2.5 

M6 

Summary of Contents for ALUPRES-EX Series

Page 1: ...xed installation ALUPRES EX Series ATEX EXECUTION CONTENITORI CON MODO DI PROTEZIONE nR Per installazione fissa Serie ALUPRES EX ESECUZIONE ATEX Execution Esecuzione Group II Category 3G 2D Ex nR IIC Gc Ex tb IIIC Db SAFETY USE and MAINTENANCE INSTRUCTIONS ISTRUZIONI DI SICUREZZA USO E MANUTENZIONE IN COMPLIANCE WITH THE DIRECTIVE 2014 34 EU PALAZZOLI S p A Via F Palazzoli 31 25128 BRESCIA Italy T...

Page 2: ... 60079 series for presumption of conformity to 2014 34 EC which provides a level of protection against explosive atmospheres ignition suitable for the installation in the declared Zone Apparecchiatura progettata e costruita in accordi con le norme armonizzate della serie EN 60079 per presunzione di conformità alla direttiva 2014 34 UE che garantisce un livello di protezione contro le atmosfere esp...

Page 3: ...rea in cui durante le normali attività è probabile la formazione di un atmosfera esplosiva consistente in una miscela di aria e di sostanze infiammabili sotto forma di gas vapore o nebbia Zone 21 A place in which an explosive atmosphere in the form of a cloud or combustible dust is likely to occur in normal operation occasionally Area in cui occasionalmente durante le normali attività è probabile ...

Page 4: ...sonale esperto formato e addestrato alla regola dell arte alle leggi norme nazionali e o internazionali applicabili per esempio EN 60079 14 Atmosfere esplosive Parte 14 Progettazione scelta e installazione degli impianti elettrici TABLE OF ZONES WHERE THE PALAZZOLI ENCLOSURES CAN BE INSTALLED TABELLA DELLE ZONE DOVE I CONTENITORI POSSONO ESSERE INSTALLATE 2014 34 EU Group and Category 2014 34 UE G...

Page 5: ...n cable M16x1 5 Pressacavo M16x1 5 su cavo 2 5 ND Cable gland on cable M20x1 5 Pressacavo M20x1 5 su cavo 3 5 ND Cable gland on cable M25x1 5 Pressacavo M25x1 5 su cavo 4 ND Cable gland on cable M32x1 5 Pressacavo M32x1 5 su cavo 8 5 ND Cable gland on cable M40x1 5 Pressacavo M40x1 5 su cavo 10 ND The equipment shall be installed according to this instructions This equipment is intended for fixed ...

Page 6: ...LI PER UN USO SICURO Assembly and start up must only be done by experienced and authorised personnel according to the applicable code of practice national rules and or international standards and on the basis of these instructions Position the equipment so that they are easily accessible for cleaning and maintenance operations Install the equipment as far away as possible from heat sources or area...

Page 7: ...ent requires grounding The equipment is provided with an internal connection terminal for earthing for earthing of circuits load if required by relevant code of practice The conductors must be equipped with ring terminal Tighten the screw of the earthing terminal with the tightening torque indicated in clause 2 of this document L apparecchiatura richiede messa a terra L apparecchiatura è provvista...

Page 8: ...cambio Check that the screws are in place free of corrosion Controllare che le viti siano in corretta posizione e non corrose Each time the enclosure is reclosed Ogni volta la custodia viene aperta e richiusa In case of fault contact manufacturer for substitution In caso di guasto contattare il costruttore per il ricambio Check that the screws are tight with correct torque Controllare che le viti ...

Page 9: ...ative pressure of 3 kPa 3 mbar o Stop the application of the negative pressure o Verify that the time interval required for return to half the initial value shall be not less than 90 s Quando montate in quadri presa come punto di test di respirazione limitata si deve utilizzare la bocca presa Per l esecuzione del test una speciale attrezzatura finta spina deve essere usata si rimanda alle istruzio...

Page 10: ...vuoti in lega d alluminio Code Codice External dimensions Dimensioni esterne mm Equipment protection Level Livello di Protezione delle apparecchiature EPL 511914EX 125x125x113 Gc Db 511919EX 252x125x113 Gc Db TECHNICAL DATA CARATTERISTICHE TECNICHE Insulating class Classe Isolamento I Degree of protection IP code Grado di protezione codice IP IP66 Satisfies the Requirements defined by following Di...

Page 11: ...imensioni esterne mm Equipment protection Level Livello di Protezione delle apparecchiature EPL 511914EX 125x125x113 Gc Db 511919EX 252x125x113 Gc Db TECHNICAL DATA CARATTERISTICHE TECNICHE Insulating class Classe Isolamento I Degree of protection IP code Grado di protezione codice IP IP66 Satisfies the Requirements defined by following Directives Soddisfa i Requisiti definiti dalle seguenti Diret...

Page 12: ...losive Parte 31 Apparecchi con modo di protezione t destinati ad essere utilizzati in presenza di polveri combustibili In addition the products covered by this declaration are in conformity with the following IEC standards I prodotti oggetto della presente dichiarazione sono in oltre conformi alle seguenti norme IEC IEC standard Norme IEC ed Title Titolo IEC 60079 0 2011 ISH1 2013 ISH2 2014 COR 20...