6.5
Foot Control installation
After installing the platform, connect the wiring harness from the platform to the connections at the liftarm.
(see page 24). Each foot switch has a hot wire (#4) on plug J3. Switch (1) connects in addition to port #5 on
J3; switch (2) connects to port #6 on J3. Make sure that connections are wire tied together and pushed in-
side the platform.
DOWN:
Step on switch 1 and hold
– wait between one and
three seconds before you step on switch 2.
UP:
Step on switch 2 and hold
– wait between one and
three seconds before you step on switch 1. If platform tip is tilted to ground,
platform will tilt up to preset position before rising.
IF BOTH SWITCHES ARE NOT ACTIVATED
BETWEEN ONE TO THREE SECONDS, START OVER.