ILP 25/33 Installation Manual
Rev. 1.4
- 25 -
1a. Maneuver the liftgate under the vehicle and position both liftarms flush to both the bed extension
upstops and the underside of the bed extension. Measure the gap between the bed extension and
platform to confirm the gap is within the acceptable range,
Fig.16
.
1/8"-1/4"
Acceptable Gap
Maintain Platform
and Bed Extension Leveled
Bed Extension
Upstop
(both sides)
Bed Extension
Liftarm
Vehicle
Body
Platform Main
1b. Clamp Platform
: Clamp 3” channels over the bed extension and platform on the street side and
curbs side of the bed extension so the relationship between the bed extension and platform is
locked and maintained throughout the installation procedure,
Fig.17.
3" Channel
Front Edge
of Platform
Clamp
Rear Edge of
Bed Extension
Clamp
Fig.16
Fig.17