4. Frame Cap
: Cap both frame cut outs with two pieces of ¼” flat bar and two 2”x3”x3/16” angles.
Install the 2” side of the angle on the outside of the frame. Weld components to the chassis and the
body long rail. Flatbar may not be required if the frame cut out does not have a step.
Note: Palfinger Liftgates does not supply cap materials. All material must be supplied by end
users.
Chassis
Wooden Spacer
1/4" Thk
Flat Bar
2"x3"x3/16"
Angle
Chassis
Wooden Spacer
1/4" Thk
Flat Bar
2"x3"x3/16"
Angle
Sill
Vehicle Frame Cutout
Rear of Vehicle
Body Long Rail
3.00"
H"
1/4"
H" to be determined by
frame cut out
3.00"
2.00"
Flat Bar
Angle
3/16"