ILP 25/33 Installation Manual
Rev. 1.4
- 53 -
Routing Switch Harnesses to Pump and Motor
1. Route each harness to the hydraulic power unit enclosure and secure harnesses with the supplied
cable ties. Keep harnesses away from sharp corners and moving parts.
2. Feed the harnesses through the cable entry slots on the enclosure as shown,
Fig.45
.
3. Wire switches accordingly per Wiring Diagrams in Sections
13.9-13.10.
Toggle Switch
Cab Shutoff Switch
(Truck)
Shutoff Switch
(Trailer)
Power Cable
OR
Fig.45