Installation Dimensions
Revision 1.3
- 11 -
4.3
Installation Dimensions 800mm arm ILP – ROUND TUBE MAIN FRAME
Ground
Clearance
"F" Dim.
*Mount
Clearance
End of Body to
Front of Mount
Plate
Figure 6 Mounting dimensions 800mm arm
NEVER exceed any of the dimensions from the
table
*
Use Mount Clearance for pre-install clearance issues
(i.e. spring hangers, fuel fills, C/M bolts, etc.)
Bed Height
Ground
Clearance
„F“
Dimension
38
12
22
39
13
22
40
14
22
41
15
22
42
16
22
43
17
22
44
18
22
45
19
22
46
19
23
47
19
24
48
19
25
49
19
26
50
19
27
51
20
27
52
20
28
53
20
29
Mounting Dimensions
STAY WITH THE „F“ DIMENSION
Minimum bed height is when truck/trailer is loaded to MAX GVW
Mounting Dimensions
ILP with 800 mm (31.5”) arm, 48" (1200 mm) platform
Bed Height F-Dimension
Cut-out X
vertical
Cut-out Y
horizontal
Mount Clearance
Ground
Clearance
38 to 47.5
22
12
17.5
38.5
12 to 20
40 to 48.5
23
14
16.5
37.5
13 to 20
42 to 50
25
15.5
15
35
13 to 20
44 to 52.5
27
17.5
13.5
33
13 to 20
46 to 53
29
19.5
12.5
32
13 to 20
•
F dimension, Mount- and Ground Clearance
always relate to each other
on a
set floor height.
If the F-dimension is increased for a shorter mount clearance, the ground clearance will decrease.
Decrease ground clearance minimally only to clear obstructions (i.e. fuel tanks, cross members, hitches,
etc.)
WITHOUT exceeding MAXIMUM “F”
dimension (29”)