Revision 1.0
28
7.2.2.2
Control board plug setup
B13 LIFT ARM B15 PLATFORM
FOOT
CONTROL
WARNING
LIGHTS
CAB ON-OFF
SWITCH TRUCK
ILUK
CONTROL
BOX
HAND REMOTE
JUMPS to
J 11 # 4
POWER PACK
GROUND for PC BOARD
(green/yellow and black # 1)
CIRCUIT BOARD K+
SECONDARY HARNESS
for SLIDE function
POSITIVE for PC BOARD
(black #2 to 2
and black # 4 to 27)
PUSH-PULL
CYLINDERS
to ON/OFF
switch
to ON/OFF
switch
CYLINDERS
LIFT 15 (2 ea)
Figure 2 Plug setup on PC - Board
This graphic describes the different functions of each plug and where it is connected to. Make sure every plug
is in its correct position and fuses are in good conditions.
Connector description:
J-1:
Main power input and connection to pump & motor tray
J-11:
ON-Off switch for truck setup
J-2:
Ground connection
J-3:
Platform equipment (foot controls)
J-30:
Control panel
J-32:
Control button input for slide function
J-4:
Lift cylinder- (#15)
J-42.1:
Output to Slide valves S-7 (slide in) and S-8 (slide out)