4) GATE IS NOT CLOSING
a) Initial Checks
→
Check Cab Switch is "ON“( Optional )
→
Check that Circuit Breaker at battery box not been tripped
→
Check that 15 amp fuse at Motor Solenoid is ok
→
Check for shorts, ground faults or open circuits, e.g., power lines connected to the ground
or a broken cable or connection
→
Check batteries. Batteries should be fully charged and in good condition
→
Check voltage - minimum 10 volts at motor at while holding the up function for 10 seconds (Deadhead)
b) Motor is not running
→
Check power supply to open/close and up/down switch and for voltage at motor solenoid and
open/close valve while activating up function
→
Check motor solenoid. If it is getting power but you do not hear click, you should change the motor
solenoid.
→
You hear it click, check if the motor gets power. If yes, check the motor of correct function.
d) Motor is running, but platform does not close
→
Check for power at open/close valve
→
Check cylinder for leaking, loose fittings or contaminated restrictor
→
Check the hydraulic oil level, low level oil in the reservoir
– fill up and activate closing function