24
ILM
plus
Series
Pump Pressure adjustment
The pressure on the pump is set at the factory and normally no adjustment is needed. If you feel
adjustment is necessary please contact Palfinger Field Technical support person in your area which will
be listed on last page of this document before proceeding with adjustment.
Tools required for adjustment
13 mm wrench
¼ Allen wrench
5/32
Allen wrench
Palfinger Part required for gauge
connections
1- HYD gauge PD-3121327
1- Adaptor fitting PD-312329
1- Elbow fitting PD-75082871
Removing adjustment cap nut
with 13 mm wrench
Adjustment 5/32 Allen wrench
Raise platform until secure in stored position with safety latch
down. Loosen allen wrench one turn Counter Clockwise while
motor running, tighten clockwise back one turn to flush. Tighten
1/4-1/2 turn more Clockwise to increase PSI to lift load