7
1) GATE DOES NOT OPEN UP
b) Platform is not opening up
→
Check if both valves on cylinder are energized.
→
If not, check power supply to switches and signal line to valves while activating open function
→
Valves are energized
– check grounding of valves
→
Valves are energized, but Platform still does not open
→
Check coil for damage and magnetic function
→
Check Gas Shocks on side of platform for damage or seized
→
Check open /close cylinder for damage or leaks
a) Initial Checks
→
Check Cab Switch is "ON“ ( Optional )
→
Check that Circuit Breaker at battery box has not been tripped
→
Check that 15 amp fuse at Motor Solenoid is ok
→
Check for shorts, ground faults or open circuits, e.g., power lines connected to the ground
or a broken cable or connection
→
Check batteries. Batteries should be fully charged and in good condition
→
Check voltage - minimum 10 volts at motor when closing or up function is engaged for 10 sec with gate
in stored position.
ILM
plus