3) GATE IS NOT RAISING UP
b) Motor does not run
→
Check power supply to up/down switch and for voltage at signal line to motor solenoid
while activating up function
→
Check motor solenoid. If it is getting power (small connector at solenoid has voltage) but you do not
hear a click, you should change the motor solenoid.
→
You hear it click - check if the motor gets power. If yes, check the motor of correct function.
c) Motor runs but platform does not raise
→
Check lift cylinder for damage or chain for broken chain links. ( See drawings page 15 & 16 )
a) Initial Checks
→
Check Cab Switch is "ON“( Optional )
→
Check that Circuit Breaker at battery box has not been tripped
→
Check that 15 amp fuse at Motor Solenoid is ok
→
Check for shorts, ground faults or open circuits, e.g., power lines connected to the ground
or a broken cable or connection
→
Check batteries. Batteries should be fully charged and in good condition
→
Check voltage - minimum 10 volts at motor after 10 sec holding the switch for closing function.
(Deadhead the gate in actual position)