Before switching on
Fault
Possible cause
Remedy
Optical indication in
driver's cab flashes
rapidly
Tilt sensor b15 defective
Replace tilt sensor b15
Switching on
(LED on PC board flashes with the same rate as the turn signal)
Fault
Possible cause
Remedy
LED on PC board does
not flash
Fuses in unit e1 or e2 have
tripped
Replace fuses
PC board in sealing cover defec-
tive
Replace PC board
Open
(platform opens until reaching operating position)
Fault
Possible cause
Remedy
Platform does not open
with motor
Output J1/3 does not deliver out-
put signal
Use test lamp to check accord-
ing to circuit diagram
Motor contactor defective
Check motor contactor
Platform does not open
Pushbutton defective
Use test lamp to check contacts
in operating element according
to circuit diagram, use ground
connection JK at PC board
No voltage at valve plug S4 or
S5, defective cable
Check with test lamp
Control valve S6 or pressure
valve locked
Clean or replace
Warning lights on plat-
form are not flashing
when platform is open
Tilt sensor b15 at the platform
misadjusted or defective
Adjust or replace
PC board defective
Replace
Plugs defective
Replace
Warning lamps are defective
Replace
Betriebsanleitung_Hubladebuehnen_EN.book Seite 164 Donnerstag, 15. August 2019 4:04 16
Summary of Contents for MBB C 1000 S
Page 3: ...Betriebsanleitung_Hubladebuehnen_EN book Seite 3 Donnerstag 15 August 2019 4 04 16...
Page 41: ...41 Betriebsanleitung_Hubladebuehnen_EN book Seite 41 Donnerstag 15 August 2019 4 04 16...
Page 63: ...63 Betriebsanleitung_Hubladebuehnen_EN book Seite 63 Donnerstag 15 August 2019 4 04 16...
Page 77: ...77 Betriebsanleitung_Hubladebuehnen_EN book Seite 77 Donnerstag 15 August 2019 4 04 16...
Page 81: ...81 Betriebsanleitung_Hubladebuehnen_EN book Seite 81 Donnerstag 15 August 2019 4 04 16...
Page 85: ...85 Betriebsanleitung_Hubladebuehnen_EN book Seite 85 Donnerstag 15 August 2019 4 04 16...
Page 89: ...89 Betriebsanleitung_Hubladebuehnen_EN book Seite 89 Donnerstag 15 August 2019 4 04 16...